6.
Measure distance "X" from the cabinet floor to the top of the
countertop. Subtract 28
1
2
dimension "Y" (X - 28
= Y).
1
2
Downdraft
vent
28
"
1
2
(73 cm)
7.
Attach the support legs to the side of the vent box with
4 - 4 x 8 mm screws in each support leg. Adjust to dimension
"Y" from the bottom of the vent box to the bottom of the support
legs. Tighten screws.
A
Determine which vent direction
is best for your installation
When installed in a cabinet, vent system can exhaust through the
bottom, right or left of the cabinet.
IMPORTANT: When using the 6" (15.2 cm) vent transition (supplied)
for 6" round venting, only left or right venting is recommended.
Bottom venting
NOTE: If installing the vent damper in the down position, a wall or
roof cap with a damper at the exit end of the vent system is required.
Downdraft vent is shipped with blower in down venting position so
no modification is required.
If rear mounting of the blower motor is not required, go to the
"Complete Installation" section.
To mount the blower motor to the rear side of the vent box, go to
the "Rear Mounting (reversible mode)" section.
" from distance "X" to determine
Top of countertop
"X"
"Y"
Cabinet floor
C
B
dim. "Y"
A. Motor box
B. Support leg
C. Installation screws
Left or right venting:
1.
Using two or more people, place the downdraft vent system on its
back.
2.
Remove the 4 screws from the cover plate mounted to the face of
the motor box and set them aside.
G
F
E
C. Cover plate keyhole slot shoulder screws
3.
Slide the cover plate up and slip it over the keyhole slot shoulder
screws. Set the cover aside.
4.
Remove 4 screws from the bottom of the motor box that hold
the motor assembly to the motor box.
NOTE: Disconnect the electrical wiring connection from motor if
needed.
5.
Remove 3 screws and the vent cover plate from the left or right
side of the motor box for the venting direction to be used.
6.
Rotate the blower motor assembly 90 degrees to the left or right
side to the chosen venting direction and secure to the blower box
with motor mounting screws previously removed. Do not twist or
bind the wires.
7.
Install the vent cover plate over the rectangular opening in the
bottom of the motor box and secure with vent cover screws.
NOTE: Reinstall the electrical wiring connection to motor if
removed.
8.
Reinstall the cover plate to the face of the motor box and secure
with 4 cover plate screws previously removed.
8
D
A.Cover plate
B. Cover plate screws
D.Motor mounting screws
E. Vent cover plate
F. Motor box
G. Vent cover screws