Problem
The surface control
light does not switch on
when the power tool is
started and the LED
may light up green.
If problems other than those listed occur, please contact a Festool service workshop or local spe­
cialist dealer, see Section 10.
Possible causes
Surface control light auto-
start function is deactivated
in the Festool Work app.
The surface control light is
faulty.
Remedy
To switch to factory settings, see Section
see the Festool Work app.
Have the surface control light replaced by an au­
thorised customer service workshop.