Flame characteristics
The color of the flame tells you if the gas supply is properly adjusted.
Note: Allow the appliance to operate for 4 to 5 minutes before evaluating the flame. Some yellow streaking is normal
during the initial startup.
Flame
Image
Completely or mostly
yellow
Yellow tips on outer
cone
Soft blue
4.9 Checking the installation
Check if your unit is working properly after you have
completed the installation steps.
WARNING
Before you turn on power supply, make sure all controls
are in the OFF position.
Ensure that the burner caps are properly positioned.
1.
Turn each burner on in turn and verify that the electric
2.
igniters are working.
Push down the control knob and turn it counter-
clockwise to the ignition symbol ⁠ .
Verify that the igniter/spark module clicks.
Once the air has been purged from the supply lines,
verify that the burner lights within 4 seconds.
When the burner lights, turn the control knob back to
the off position.
If any of the burners do not ignite, do not continue
testing. Call Customer Service.
Turn the control knob between the highest and lowest
3.
setting. Make sure the flame does not go out and there
are no flashbacks.
If you have carried out an LP gas conversion, check the
4.
lowest setting to confirm the flames are stable on the
ports and the set screws do not need to be readjusted.
Check the flame characteristics.
5.
The flame should be blue with a minimal yellow tip on
the outer cone.
After completing all checks, complete the installation of
6.
the horizontal panel or oven. →  Page 9
Note: The appliance is shipped from the factory for use
with natural gas. If you want to use propane gas, it must
be converted. A qualified technician or installer must do
the conversion. Refer to Conversion to LP gas.
Measure
Verify that the regulator is set for the correct fuel. Retest
after adjustment.
Normal for LP gas
Normal for natural gas