Télécharger Imprimer la page

Desa RCLP50A Manuel Du Propriétaire page 6

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
6
Review and understand the warnings in the Safety Information
Section, pages 2 and 3. They are needed to safely operate this
heater. Follow all local codes when using this heater.
Test all gas piping and connections for leaks after installing
or servicing. Never use an open flame to check for a leak.
Apply a mixture of liquid soap and water to all joints.
Bubbles forming show a leak. Correct all leaks at once.
1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL
fitting counterclockwise into threads on tank. Tighten firmly using a wrench.
IMPORTANT:
Position regulator so that hose leaving the regulator is in a
horizontal position (see Figure 3). This places the regulator vent in the proper
position to protect it from the weather.
Propane
Supply
Valve
Propane
Tank
3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT:
Use extra hose or piping if needed. Install extra hose or piping
between hose/regulator assembly and propane tank. You must use the regula-
tor supplied with heater.
Inlet Connector
Figure 4 - Hose and Inlet Connector
WARNING
WARNING ICON
G 001
WARNING
WARNING ICON
G 001
Figure 3 - Regulator Position
Hose
Regulator
Hose
POL Fitting
102401

Publicité

loading