Télécharger Imprimer la page

Leister WELDPLAST S2 Instructions D'utilisation page 20

Masquer les pouces Voir aussi pour WELDPLAST S2:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
Welding preparation
The temperature control prevents the hand extruder from being started while it is cold.
Drive status
display (30)
Heating until ideal
values are reached
The device heats up to the last ideal temperature set directly after switching on the main switch (1). When the
ideal temperature is reached, a counter on the status display counts back from 220 seconds to zero. After this
start-up process is complete, the device is ready to weld (status Ready*). The hand extruder takes around 5 minutes
to reach its temperature range.
If the power is only turned off for a short time, the start-up process does not need to be repeated.
Software and menu guide
The hand extruder Weldplast S2 is provided with a convenient user software, making work easier for the user. Tap
lightly on the keys to operate them.
Workspace functions
Menu selection
Set contrast
Heating on/off
Change cursor position
Selected value [+]
Selected value [–]
Start window
After turning on the hand extruder
with the main switch (1), the device
name and current software version
will be displayed for 3 seconds.
Setting the parameters in the workspace
The cursor (31) shows which parameters can be
set. After the device is switched on, the cursor is
situated on «SPEED». «AIR» or «PLAST» can be
selected with the Select key (28) and their values
can be changed using the Up key (29) or Down
key (27).
20
All manuals and user guides at all-guides.com
Start-up waiting period: 220 seconds
Motor disabled
Heating
Menu selection functions
Menu selection / Back to workspace
Back to workspace (changes not saved!)
Select and back to workspace
Select
Cursor up / Selected value [+]
Cursor down / Selected value [–]
M free
Motor release
Workspace
The workspace shows the
parameters which are
currently set.
Set value
Set value
Ready*
Ready to weld
Set value

Publicité