Télécharger Imprimer la page

AirKing AKF950 Manuel D'instructions page 3

Publicité

Les langues disponibles

Les langues disponibles

Ground
White
Black
WALL SWITCHES
(by others)
Figure 5
NOTE: Two of the wire connectors inside the unit wire compartment have ground wires that
should already be connected to a ground screw on the units's housing. Confirm that these
wires are in place and still connected.
4.
Carefully tuck wire back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
NOTE: Unit must be grounded according to all local and national codes.
SECTION 6
Completing the Installation
1.
Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan
be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.
Make sure the 3 pin blower assembly (smaller connector) and the 3 pin heater assembly
(larger connector) are plugged into the corresponding receptacle (wire connector)
located on the interior wire compartment cover. Also confirm that the 5 pin connector
coming from the blower is connected to the capacitor on the side of the housing. These
cords will only fit one way into the receptacles (Figure 6).
Figure 6
3.
Remove the two screws that connect the ceiling mounting flange to the housing. Put
sealant (not provided) on inside edge of the ceiling mounting flange to ensure that the
flange is sealed to the ceiling. Line up the screw holes in the ceiling mounting flange with
the screw holes on the inside of the housing and press flange in place so it is tight against
the ceiling. Reinstall ceiling flange mounting screws inside the housing (Figure 7).
Ceiling
Mounting
Flange
Figure 7
6727906 Rev. C 11-18
All manuals and user guides at all-guides.com
Ground
White
White
White
Orange
Red (night light)
Blue (light)
Black (fan)
Yellow (heater)
HEATER UNIT
By others
Screws
Screw Holes
www.airkinglimited.com
NOTE: If the housing is mounted too far or not far enough into the ceiling for the flange to
make a solid connection, loosen the mounting channel and adjust the housing up or down on
the rails. Once in place, fully tighten the mounting channel nuts.
4.
Install the grill by squeezing the springs together and installing it up into the slot furthest
from the wire compartment on the fans housing. Attach the 6 pin quick connect from the
grill to the 6 pin connector on the top of the wire cover. The cord will only fit one way into
the receptacle. Install the other spring and push the grill up into position (Figure 8).
Figure 8
6.
Open the light lens on the grill by pushing into the lens and allowing in to spring open.
Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins
on the lamp base to the socket of the lamp holder and pressing towards the lamp holder
until the lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt
maximum type C7 (candelabra base) night light (not included) into the side lamp holder.
5.
Restore power and test your installation.
SECTION 10
Use and Care
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid,
1.
and wipe with a damp cloth. NEVER IMMERSE ELECTRICAL PARTS IN WATER. NEVER USE
ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling.
Refer to instructions in Section 6 Completing the Installation, to reinstall grill.
Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan.
2.
NEVER IMMERSE ELECTRICAL PARTS IN WATER.
CAUTION:
ALLOW BULBS TO COOL BEFORE REPLACING.
3.
Changing the Lamp: Disconnect power to the unit. Open the light lens on the grill by
pushing into the lens and allowing in to spring open.
Fluorescent Bulb: Remove lamp by gently rocking lamp back and forth while applying
outward pressure to release the lamp from the base. Replace with Air King model 26EFL
or Espen Technology model CFQ26W/827.
Night Light: Unscrew night light bulb from socket and replace with a 4 watt maximum
type C7 (candelabra base) night light bulb.
NOTE: The heater function is equipped with an energy
saving fan off time delay. When the heater function
is turned off the heating element will turn off but the
blower will continue to run for an additional 30 seconds
delivering any residual heat to the occupied space.
MAKE SURE POWER IS SWITCHED OFF AT
3 of 12

Publicité