Electrical safety procedures &
requirements
The use of the BEEM® requires an electrical installation with reliable safety
grounding. The installation's electrical safety can only be guaranteed
if the device has been correctly connected to an earthing system built
in accordance with the safety instructions. A preliminary inspection is
absolutely essential. In the event of any uncertainty, a careful inspection
must be made by a qualified and authorised technician. Heatsail will not be
held responsible for injury and/or damage resulting from an ungrounded
installation.
The installation of the BEEM®'s electrical components requires a mains
connection of 230V-50/60Hz (16 Amp fuse EN 30 mA RCD): the connection
must be properly implemented in accordance with the applicable IEC-CEI
standards. Please note: statutory and other regulations may apply locally.
The electrical power supply will need to be interrupted before the
connection or other work on the electrical components can be carried-out
and everyone must satisfy themselves that the power can't be switched
on again accidentally.
The use of adapters, power strips and extension leads may not be used
for the BEEM®'s electrical supply. A switch must be installed between the
BEEM® and the fuse box at all times. Non-compliance with these
instructions may compromise the safety of the device. Heatsail will not be
held liable for any damage resulting from this.
2.
Safety
A compulsory minimum clear height of 1.85 meters must be observed
for the BEEM®, measured between the ground and bottom of the lowest
heating element.