1 Introduction
This manual is applicable to the installation of connection kits for
rigid fuel tanks.
The tank may be made from plastic, GRP or metal and should have a
minimum wall thickness of 1.5 mm (
2 Installation
2.1 Cutting the hole for the connector lid
Position the connector lid on the top face of the tank. If a VETUS tank
is used, then it should be fitted with plug P on the top and the con-
nector lid should preferably be located so that plug P is removed
when the hole is cut.
Cut the hole in the tank and remove all burrs.
Preferably use a holesaw ( 114 mm, 4
Clean the inside of the tank before fitting the connector lid.
2.2 Rubber seal to be applied
Determine the thickness of the wall of the tank and use the indicated
rubber seal.
2.3 Installation of connector lid
• Connector lid (5)
Position connector lid (5) into the hole in the tank.
Tighten each of the 3 screws (6) one (-1-) revolution (clockwise)
and check if the lid can be rotated easily by hand.
Repeat this until the lid can't be rotated anymore. Check that the
inlet connection is facing in the required direction. Then tighten
each of the screws another two (-2-) revolutions.
4
040106.02
1
/
").
16
1
/
" diam.).
2
Consult the manual supplied with the diesel fuel tank for instruc-
tions on how to connect it.
ø 114 (4
MIN. 135
(5
5
/
")
16
T
T = 1.5 - 4 mm
(
1
/
"-
5
/
")
16
32
T = 4 - 10 mm
(
5
/
"-
3
/
")
32
8
4
6
5
N
!
ote
1
/
")
2
P
vetus® Connector kits FTLxxxx