1.4 Product description of hand pump
The K10C CEMO horizontal is a hand-operated
pump for the delivery and dispensing of fuels and
similar materials from storage containers.
In order for the pump to function, a non-return
valve is integrated on the outside of the tank on the
suction side.
Suction side M20x1
female thread
All manuals and user guides at all-guides.com
Name plate
Hand lever
Pressure side
DN 19
Due to the requirements regarding operation and
the selected protection category, "design safety - c"
as per DIN EN 13463-5, the pump is provided with
the following labelling:
II 2 G Ex c T3
Permissible ambient temperature:
- 10 °C to + 40 °C
Impermissible media temperature: depending on
the medium (hazard class A I to A III)
- 10 °C to + 40 °C
Important!
Risk of explosion!
The pump must not become
hot during operation.
Do not deliver any impermissible
heated media.
Important!
Explosive atmospheres may only
occur occasionally within the pump.
Therefore, operation without liquid is
only permitted for brief periods of time.
Important!
i
Persistent running on empty can lead
to the destruction of the pump.
GB