Télécharger Imprimer la page

Thermador Professional Serie Instructions D'installation page 17

Masquer les pouces Voir aussi pour Professional Serie:

Publicité

Les langues disponibles

Les langues disponibles

Installing the integral blower
Integral blower models are integrated into the hood at the
time of installation. Integral blowers should be installed
after the hood is mounted to the wall. For complete
installation instructions, see the instructions supplied with
the blower unit.
Note: Blower and hood image views vary depending on
model.
Thread one (1) 4m flange nut (included with the hood)
1.
half-way down each of the two weld studs indicated.
Slide the blower mounting plate behind the nuts on the
2.
weld studs.
Install two (2) 4m flange nuts (included with hood) to the
3.
top weld studs and tighten.
Tighten the two (2) nuts from step 1 to fully secure the
4.
blower to the hood.
Connect the blower's plug connector to the connector
5.
present inside the hood. Route the blower harness
through the self-locking clip.
Installing a remote blower or an in-line blower
Depending on preference and ducting situation these
blowers can be installed outside the kitchen. This reduces
the noise in the kitchen. For complete installation
instructions see the instructions supplied with the blower
unit.
Remote blower
1.
Remote blowers can be mounted on the roof or exterior
wall of the home
Installation en-us