8) Technical characteristics
Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In
any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
All the technical characteristics refer to an ambient temperature of 20°C (±5°C)
Technical characteristics: ROBUS
Model
Type
Pinion
Peak thrust
[corresponding to the ability to develope a
force capable of moving the leaf]
Nominal torque
[corresponding to the ability to develope a force
capable of maintaining the movement of the leaf]
Nominal torque speed
Idling speed (the control unit allows 6 speeds
to be programmed, approx. equal to: 100, 85,
70, 55, 45, 30%) 70, 55, 45, 30%)
Maximum frequency of operating cycles
(nominal torque)
Maximum continuous operating time (nomi-
nal torque)
Operating limits
Durability
ROBUS 600 – 1000 power supply
ROBUS 600 – 1000/V1 power supply
Thrust maximum absorbed power [equiva-
lent to amperes]
Insulation class
Emergency power supply
Flashing light output
Open Gate Indicator Output
BLUEBUS Output
STOP input
Step-by-step Input
OPEN input
CLOSE input
Radio connector
Radio AERIAL Input
Programmable functions
Self-Recognition functions
Operating temperature
Use in acid, saline or potentially explosive
atmosphere
Protection class
Dimensions and weight
24
RB600 – RB600P
Electromechanical gearmotor for the automatic movement of sliding gates for residential
use, complete with electronic control unit
Z: 15; Module: 4; Pitch: 12.6 mm; Pitch diameter: 60mm
18Nm
[600N]
9Nm
[300N]
0,15m/s
0,31m/s
100 cycles / day (the control unit allows up to
the maximum described in tables 2 and 3)
7 minutes
(the control unit limits the continuous operation
up to the maximum described in tables 2 and 3)
In general, ROBUS is suitable for the automation of gates featuring weights or lengths as
shown in Tables 2, 3 and 4
Estimated between 20,000 and 250,000 cycles, following the conditions indicated in
table 4
230Vac (+10% -15%) 50/60Hz.
120Vac (+10% -15%) 50/60Hz.
515W [2,5A] [4,8A versione /V1]
1 (a safety grounding system is required)
With PS124 optional accessory
For 2 LUCYB flashing lights (12V, 21 W lamp)
for one 24V maximum 4W bulb (the output voltage may vary between –30 and +50%
and can also control small relays)
One output with a maximum load of 15 BlueBus units
For normally open contacts, for 8,2K ; constant resistance, or normally closed contacts; with
self-recognition (any variation from the memorized status causes the "STOP" command)
For normally open contacts (the closing of the contact causes the "STEP-BY-STEP" command)
For normally open contacts (the closing of the contact causes the "OPEN" command)
For normally open contacts (the closing of the contact causes the "CLOSE" command)
"SM" connector for SMXI and SMXIS receivers
52
for RG58 or similar type of cable
8 ON-OFF functions and 8 adjustable functions (see tables 7 and 9)
Self-recognition of the type of "STOP" device (Normally Open, Normally Closed contact
or 8,2K ) Self-recognition of the gate length and calculation of the deceleration points
and the partial opening point.
-20°C ÷ 50°C
No
IP 44
330 x 210 h 303; 11Kg
RB1000 – RB1000P
27Nm
[900N]
15Nm
[500N]
0,14m/s
0,28m/s
150 cycles / day (the control unit allows up to
the maximum described in tables 2 and 3)
5 minutes
(the control unit limits the continuous operation
up to the maximum described in tables 2 and 3)
450W [2,3A] [4,4A versione /V1]
330 x 210 h 303; 13Kg