3. Technical data

3. Technical data
3.1 Transmitter
1)
Power supply U B
Supply voltage effect
Permissible residual ripple
Output signal, variant I
Permissible max. load R A
Effect of load
Output signal, variant II
Output signal, variant III
Output signal, variant IV
Impendance on the voltage output
Load-carrying ability voltage output
Sample rate sensor
Electrical zero point
Zero point adustable range
Linearity
Output signal accuracy
Resolution
Update rate (measuring rate)
Input signal rotational angle
Expanded special span
Long-term stability of electronics
Temperature error, electronics
Warming-up time
Permissible ambient temperature
Permissible storage temperature
Permissible medium temperature
Special function
CE-conformity
Wiring
Wiring protection
Connection details,
depending on variant
1) Not model PGT.06
) Not model DPGT4HP.100 / DPGT4HP.160
WIKA Operating Instructions intelliGAUGE family
1 ≤ U B ≤ 30
DC V
≤ 0.1
% of FS/10 V
≤ 10
% ss
4 ... 0 mA, -wire, passive, per NAMUR NE4
R A ≤ (U B - 1 V)/0.0 A with R A in Ohm and U B in Volt
however max. 600 Ω
≤ 0.1
% FS
4 ... 20 mA, 2-wire - Ex, per ATEX Ex II 2G Ex ia IIC T4/T5/
T6 or Ex I M Ex ia I
0 ... 0 mA, -wire
0 ... 10 V *
0.5
kΩ
 ... 100
ms
600, with -wire optionally faster
Zeroing through short-term jumper across ternimals 5 and 6
< °
45
)
≤ 1.0 (limit point calibration)
% of span
% FS
0. (only electronic)
% FS
0.15 (10 bit resolution at 60°)
1/s
> 1
0 ... 70
< °
)
< °
< 0 (Option)
)
% FS/a
< 0.
% FS/10K
< 0. (over the complete temperature range)
≤ 5
min.
°C
-40 ... +60
°C
-40 ... +70
°C
-40 ... +100
Option: non-proportional angular output signal, via auxili-
ary points and interpolation of the intermediate values (to
specify with the order)
Interference emission and immunity per EN 61 6-1
L-plug connector, 180 °C rotatable, max. 1.5 mm², wire
protector, Cable gland M0 x 1.5, External cable diameter
7-1 mm, incl. strain relief
IP65 to EN 60 59 / IEC 59;
Protected against reverse polarity and overvoltage
Terminal
Variant I
No
4 ... 0mA
1
GND

I+
reserved

4
reserved
5
Zeroing
Zeroing
6
)
Ex-Variant II
Variant III
4 ... 0mA
0 ... 0 mA
GND
GND
I+
U B +
reserved
I out
reserved
reserved
Zeroing
Zeroing
Zeroing
Zeroing
GB
Variant IV
0 ... 10V
GND
U B +
U out
reserved
Zeroing
Zeroing
5