Technical Data And Use In Accordance With Intended Use; Pressure Connection - WIKA 5 Instructions D'utilisation

Manomètres avec seuil d'alarme inductif
Masquer les pouces Voir aussi pour 5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Technical data and use in accordance with intended use

3. Technical data and use in accordance with intended use
Working pressure
Model 43X.50/30: Steady:
Fluctuating:
Overpressure safety: see data sheet PM 05.02

Pressure connection

T
According to the general technical regulations for pressure gauges,
respectively (i.e. EN 837-2 "Selection and installation recommendations for
pressure gauges").
When screw-fitting the gauges the force required for sealing must not be
applied through the case or terminal box but, using a suitable tool, only through
the spanner flats provided for this purpose at the square of the connector.
Installation with
open-end wrench
Temperature effect
When temperature of the pressure element deviates from reference temperature
(+20 °C): max. ±0.8 %/10 K of true scale value
IP Ingress protection
IP 54 per EN 60 529 / IEC 60 529
(with liquid filling IP 65)
WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
full scale value
0.9 x full scale value
GB
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

831532.53.160831.12