VENTILATION UNIT
When switched on the unit emits a long acoustic signal.
Through the IR controller the following functionalities can be activated/deactivated. When one setting is transferred to the unit,
a short acoustic signal is emitted and a green led flashes.
FUNCTIONALITY
Airflow direction
The unit runs in extract/intake at the selected speed: the inversion time is
Alternate
automatically defined thanks to the integrel temperature sensor.
Extract
The unit runs in extract only at the selected speed.
Intake
The unit runs in intake only at the selected speed.
Mode (active only if the airflow direction is set on alternate)
Optimisation of the acoustic and thermal comfort. The inversion time
varies automatically from 40÷120 seconds, thanks to the integrel
Comfort
temperature sensor. The first time cycle is of 120 seconds, then it varies
automatically according to the detected temperature conditions.
Optimisation of the thermal efficiency. The inversion time is fixed at about
Efficiency
70 seconds.
Continuous running speed
Speed 1: 20m
Speed 2: 30m
Speed 3: 40m
Speed 4: 50m
Speed 5: 60m
Off position
Pressing the
long acoustic signal. To re-activate the unit, press any button.
BOOST speed
The unit runs at speed 5 (maximum) for 15 minutes, in extract only;
then it returns to the previously selected mode/speed. The BOOST speed
cannot be activated if the controller is OFF.
Free cooling
The unit runs in "extract only" or "intake only" to avoid heat recovery
when not needed.
Filter reset
Every 3 months a yellow warning led switches on (fixed light) to indicate
that the filters have to be maintained. Press the dedicated button for 5
seconds to reset the timing.
Smart humidity control
When the humidity sensor detects a quick variation of the Relative
Humidity level, the running speed automatically increases to the next
higher speed. After 10 minutes from the last quick RH variation, the unit
returns running at the selected speed. The smart humidity control is active
if the airflow direction is set on alternate or extract only: if speed 5 has
been selected, no speed increase happens. To disable this functionality,
press the button for 5 seconds: on the top side of the LCD display
the
symbol is shown.
All manuals and user guides at all-guides.com
DESCRIPTION
3
/h
/h
3
/h
3
/h
3
/h
3
button for 3 seconds, the units switches off, emitting a
CONTROLLER
ICON
BUTTON
COMFORT
EFFICIENCY
+
+
+
+
+
OFF
oppure
FILTER
RESET
ACOUSTIC
LED
SIGNAL
green
short
green
short
green
short
green
short
green
short
green
short
green
short
green
short
green
short
green
short
red
long
fixed blue
short
green
short
green
short
flashing blue
9

Publicité

loading