OPERATION
Installing or removing battery
cartridge
CAUTION:
Al ays s itch o the tool before
installing or removing of the battery cartridge.
CAUTION:
Hold the tool and the battery car-
tridge firmly hen installing or removing battery
cartridge. F a i l u r e t o h o l d t h e t o o l a n d t h e b a t t e r y
cartridge firmly may cause them to slip off your hands
a n d r e s u l t i n d a m a g e t o t h e t o o l a n d b a t t e r y c a r t r i d g e
and a personal injury.
Fig.2: 1. R e d i n d i c a t o r 2. B u t t o n 3. B a t t e r y c a r t r i d g e
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
T o i n s t a l l t h e b a t t e r y c a r t r i d g e , a l i g n t h e t o n g u e o n t h e
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator as
shown in the figure, it is not locked completely.
CAUTION:
Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
y o u o r s o m e o n e a r o u n d y o u .
CAUTION:
Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
n o t b e i n g i n s e r t e d c o r r e c t l y .
Indicating the remaining battery
capacity
P r e s s t h e c h e c k b u t t o n o n t h e b a t t e r y c a r t r i d g e t o i n d i -
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Fig.3: 1. Indicator lamps 2. C h e c k b u t t o n
Indicator lamps
Lighted
O
Remaining
capacity
Blinking
75
to 100
50
to 75
25
to 50
0
to 25
Ch a r g e t h e
b a t t e r y .
T h e b a t t e r y
m a y h a v e
malfunctioned.
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when
the battery protection system works.
Description of operation
WARNING:
W ear hearing protection to protect your
ears against exhaust noise and noise during
operation.
Drain valve:
The drain valve is located at the bottom of the air tank
and is used to drain condensation at the end of each
u s e .
Automatic shut o system:
If the compressor automatically shuts off before reach-
ing its normal cutoff pressure :
1.
Turn the On/Auto-Off switch to Off position.
2.
R e m o v e t h e b a t t e r y c a r t r i d g e .
.
Wait until the compressor cools down. (about
10 m i n . )
4 .
I n s t a l l t h e b a t t e r y c a r t r i d g e .
5.
Turn the On/Auto-Off switch to On/Auto position.
ON/AUTO - OFF switch:
Turn this switch to on (I) position to provide automatic
power to the pressure switch and to off (0) position to
remove power when finished using the compressor or
when compressor will be left unattended.
WARNING:
O s itch hen not in use.
CAUTION:
When carrying the tool, turn o (0)
the On/Auto-O s itch.
Air filter (Air intake):
Keep the air filter clean at all times. Do not operate the
compressor with the air filter removed. The compressor
does not operate at full capacity if the air filter is dirty.
Before using the compressor, always check the air filter
if it is clean. If not, clean the air filter or replace the filter
e l e m e n t .
Air compressor pump:
To compress air, the piston moves up and down in the
c y l i n d e r . O n t h e d o w n s t r o k e , a i r i s d r a w n i n t h r o u g h t h e
a i r i n t a k e v a l v e . T h e e x h a u s t v a l v e r e m a i n s c l o s e d .
On the upstroke of the piston, air is compressed. The
intake valve closes and compressed air is forced out
t h r o u g h t h e e x h a u s t v a l v e , t h r o u g h t h e o u t l e t t u b e ,
t h r o u g h t h e c h e c k v a l v e a n d i n t o t h e a i r t a n k . U s e a b l e
air is not available until the compressor has raised the
air tank pressure above that required at the air outlet.
Check valve:
When the air compressor is operating, the check valve
is open , allowing compressed air to enter the air tank.
When the air compressor reaches cut-out pressure,
the check valve closes , allowing air pressure to remain
i n s i d e t h e a i r t a n k .
10 ENGLISH
Risk of Noise
Al ays turn o (0) the On/Auto-