Télécharger Imprimer la page

LORCH BasicPlus T Serie Manuel D'utilisation page 38

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 170
14
Starting up
14.1
Electrode welding process
 Select the electrode welding process with button 30 (LED
electrode- DC 33 or LED electrode- AC 34 lights up).
9 You are in the parameter main current I1 (LED Main current
I1 37 lights up).
 Use the rotary knob 41 to set the desired current intensity.
9 Your welding machine is now ready for use.
Electrode diameter [mm]
1,5
2,0
2,5
3,2
4,0
5,0
Heed the electrode manufacturer's instruc-
i i
tions.
Parameter
Main current I1
T 180
T 220 AC/DC
T 220 DC
T 250
T 300
Tab. 1:
Main parameters
The factory setting values are optimised thanks to automatic
parameters.
You can use these factory settings unchanged for most weld-
ing jobs.
Further fine adjustment facilities can be found in Chapter „14.3
Secondary parameters" on page 39.
14.2
TIG welding process
 Select the TIG welding process with button 30 (LED TIG-
DC 31 or LED TIG- AC 32 lights up).
 Select the desired mode with button 47 (LED 2-stroke 44,
LED 4-stroke 45 or LED Pulse 46 lights up).
 48 Press the main parameter button on the bottom right
until the desired parameter appears (the corresponding
LED 35 - 43 lights up).
 Use knob 41 to set the desired value.
9 Your welding machine is now ready for use.
- 38 -
All manuals and user guides at all-guides.com
Recommended current
intensity [A]
20 - 40
35 - 60
45 - 100
75 - 140
130 - 190
180 - 260
Factory
Range
LED
setting
10 - 150 A
10 - 170 A
100
37
10 - 180 A
10 - 200 A
10 - 200 A
909.2669.9-02
Recommended
Electrode
current intensity
diameter [mm]
DC [A]
1,0
3 - 40
1,6
15 - 130
2,0
45 - 180
2,4
70 - 240
3,2
140 - 320
4,0
220 - 450
*) Depending on the type of electrode and AC-Balance param-
eter setting
Parameter
Gas pre-flow time
0,1 - 10 sec.
Upslope
Main current I1
T 180
T 220
T 250
T 300
1 - 200 % of main
Second current I2
0,2 - 2000 Hz
Pulse frequency (only for
(representation
pulse mode)
Downslope
A synchronisation takes place in the DC pulse operating mode
with feed or control The current reduction always begins with I2
independent of the current status I1 or I2.
Gas post-flow time cor-
rection
Tab. 2:
Main parameters
The factory setting values are optimised thanks to automatic
parameters.
You can use these factory settings unchanged for most weld-
ing jobs.
Further fine adjustment facilities can be found in Chapter „14.3
Secondary parameters" on page 39.
Starting up
Recommended
current intensity
AC [A]
5 - 30*
20 - 90*
45 - 135*
70 - 180*
130 - 250*
200 - 320*
Factory
LED/
Range
setting
Code
0,1
35
0 - 99 %
5
36
3 - 180 A
3 - 220 A
100
37
5 - 250 A
5 - 300 A
50
40
current
5
39
0.2 - 2.0t)
0 - 500 %
20
42
20 - 500 %
100
43
01.21

Publicité

loading