Transport
9
Mains connection
The machine complies with the requirements of EN / IEC
61000-3-12 provided that the maximum network impedance
Zmax is smaller or equal to the impedance Zmax of the ma-
chine at the connecting point to the public low-voltage net-
work specified in the technical specifications. The fitter or user
of the machine is responsible to ensure that, where applicable
by coordination with the public power supplier, the machine
is only connected to a public low-voltage network when the
maximum network impedance Zmax is smaller or equal to
the impedance Zmax of the machine specified in the techni-
cal specifications. WARNING: Permanent use of the machine at
maximum performance with an actual switching period that
is greater than fifteen percent leads to the limit values for Rsce
defined according to IEC 61000-3-12 being exceeded, If the
machine is to be operated with a respectively high loading
on a public low-voltage network, the permission of the power
supplier must be obtained by the user with regard to the con-
nection of the device.
For units (type T 220) you basically do not have to consider
specific aspects regarding the power supply.
10
Noise emission
The noise level of the unit is less than 70 dB(A), measured un-
der standard load in accordance with EN 60974-1 in the maxi-
mum working point.
11
Transport
For transport using mechanical lifting
equipment (e.g. crane, ...) only the handle
may be used as the hoisting point. Use suit-
able load-carrying equipment.
Do not lift the by the housing using a fork-
lift truck or similar.
The carrying strap is exclusively for the
transport by a person.