Ambient conditions
Temperature range of ambient air:
in operation: -10 °C ...+40 °C (+14 °F ...+104 °F)
Transport
and storage: -25 °C ... +55 °C (-13 °F ... +131 °F)
Relative humidity:
up to 50 % at 40 °C (104 °F)
up to 90 % at 20 °C (68 °F)
Operation, storage and transport may only be
carries out within the ranges indicated! Use
outside of this range is considered not used
with its intended purpose. The manufacturer is
not liable for damages cause by misuse.
Ambient air must be free of dust, acids, corro-
sive gases or other damaging substances!
5
General regulation of use
The device is intended for welding steel, aluminium and alloys
in commercial and industrial application conditions.
‰ The device used for welding the following with direct cur-
rent
– non-alloyed, low-alloy and high-alloy steels,
– copper and its alloys
– nickel and its alloys
– Special metals such as titanium, zirconium and tanta-
lum,
‰ for TIG welding with AC* of
– aluminium and its alloys*,
– magnesium and its alloys*
‰ nd for MMA welding.
*) Only AC/DC
6
UVV inspection
Operators of commercially-operated welding systems are
obliged to have safety inspections of the equipment carried
out regularly in accordance with EN 60974-4. Lorch recom-
mends inspection intervals of 12 months.
A safety inspection must also be carried out after alterations or
repair of the system.
Improperly carried out accident prevention
regulation tests can lead to the destruction of
the system. For more information on UVV in-
spections of welding systems, please contact
your authorised Lorch service centre.
7
Unit protection
This machine is protected electronically against overloading.
Do not use stronger fuses than those stated on the type plate
of the device.
Before welding, connect the workpiece to the machine with
the ground cable.
- 30 -
All manuals and user guides at all-guides.com
8
This product complies with the currently valid EMC standards.
Please observe the following:
‰ Due to their high power consumption, welding machines
‰ The unit is intended for welding under both commercial
‰ Electromagnetic problems during commissioning can
If other equipment in the vicinity shows signs of interference,
additional screening may be necessary.
‰ The affected area can be bigger than your premises/prop-
Please use the machine in compliance with the manufacturer's
instructions. The machine operator is responsible for installa-
tion and use of the machine. If electromagnetic malfunctions
should occur, the plant operator (possibly with the manufac-
turer's technical assistance) is responsible for the remedial
measures.
909.2669.9-02
Electromagnetic compatibility (EMC)
Electromagnetic compatibility
(EMC)
can cause problems in the public power grid. The mains
connection is therefore subject to requirements with re-
gard to the maximum permissible system impedance. The
maximum permissible system impedance (Zmax) of the
interface to the power grid (mains connection) is indicat-
ed in the technical data. If in doubt, please contact your
power grid operator.
and industrial application conditions (CISPR 11 class A).
Use in other surroundings (for example in residential ar-
eas) may disturb other electronic devices.
arise in:
– Mains cables, control cables, signal and telecommuni-
cation lines near the welding or cutting area
– TVs/radios
– Computers and other control equipment
– Protective equipment in commercial systems (e g
alarm systems)
– Pacemakers and hearing aids
– Equipment for measurement and calibration
– Equipment with too little protection against distur-
bances