ENGLISH
"HOME" page
Upon start-up, the display shows the empty screen for about 10 seconds. It then goes to the "HOME" page.
This page allows you to view various data useful for controlling equipment. The data and information that the page can
display are indicated in the figures and table below.
Some examples of the HOME screen are shown below.
Bypass
1
Ext + 5°C
Int +22°C
Exh +18°C
Equipment start-up/shut-down
If the equipment is switched off, the "HOME" page will display "Off" at the centre.
To access equipment: : press the [▲] key from the "HOME" page. CAUTION: Upon start-up, the device will stop both motors
for 2 minutes to allow for the bypass valve to be repositioned. The motors will then activate. During this time, the message
"Off" will remain on the display and the user will not be able to make any modifications.
To switch off equipment: : press the [▼] key from the "HOME" page until the text below appears: "Off".
CAUTION: After having selected device shut-down (Off), the air is extracted at maximum speed (for about 3 minutes) in
order to dispose of the condensate accumulated in the heat recovery unit. During this time, the message "Off" will remain
on the display and the user will not be able to make any modifications.
All manuals and user guides at all-guides.com
2
03/04/2017
La figura qui sotto rappresenta le zone del
display
1
3
4
6 6 6
NoFrost
Progr
12:30
2
5
7
37