Télécharger Imprimer la page
AERMEC NRL 500 Schéma D'installation

AERMEC NRL 500 Schéma D'installation

Schema elettrico

Publicité

Liens rapides

1
A
B
C
D
E
F
1
2
3
SCHEMA ELETTRICO
STAMPATO
13/12/2013
2
3
4
5
AERMEC S.P.A.
BEVILACQUA (VERONA)
ITALY
WIRING DIAGRAM
NRL 500 - 550H
PROGETTAZIONE
SERIE
DISEGNO
4956269_00
COMMITTENTE
Sabik
PROGETTATO CON
SISTEMA CAD/CAE
REV.
DESCRIZIONE REVISIONE
4
5
6
NORME
TENSIONE
208V 60Hz
ESERCIZIO
TENSIONE
230V 60Hz
COMANDI
TENSIONE
24V
SEGNALI
RESIST. BACINELLA
DATA
FIRME
13/12/2013
DIS.
VISTO
13/12/2013
APPROV.
13/12/2013
NRL 500 - 550H
DATA
DISEGNATORE
SOST. DA:
6
7
8
PROTEZIONE
+
UBICAZIONE
=
NOME LOGICO
š4956269_00xœ
SCHEMA FUNZIONALE
TABELLE DI RIEPILOGO
MORSETTIERE, CAVI E DISPOSITIVI GENERICI
DISTINTA BASE
LEGENDA PAGINE
LEGENDA SIMBOLI
FOGLIO
0
RESIST. BACINELLA
T.F.
SOST. IL:
ORIGINE
7
8
A
B
C
D
E
F
18

Publicité

loading

Sommaire des Matières pour AERMEC NRL 500

  • Page 1 AERMEC S.P.A. BEVILACQUA (VERONA) ITALY SCHEMA ELETTRICO WIRING DIAGRAM NRL 500 - 550H NORME PROTEZIONE TENSIONE PROGETTAZIONE 208V 60Hz ESERCIZIO TENSIONE SERIE 230V 60Hz COMANDI UBICAZIONE NOME LOGICO DISEGNO 4956269_00 TENSIONE SEGNALI COMMITTENTE RESIST. BACINELLA Sabik PROGETTATO CON SISTEMA CAD/CAE š4956269_00xœ...
  • Page 2 MTC1A MTC2 I> I> I> I> I> I> I> I> I> CC1A CP1A COMPRESSORE COMPRESSOR DATA 19/11/2013 NRL 500 - 550H POTENZA DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY POWER REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV.
  • Page 3 I> I> I> VENTILATORE Per il N° esatto dei ventilatori consultare documentazione tecnica For the exact N ° of fans refer to the technical documentation DATA 19/11/2013 NRL 500 - 550H POTENZA DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00...
  • Page 4 RAP1 RAP2 RESISTENZA BACINELLA RESISTENZA CP PROTEZIONE CP HEATER DRAIN CP PROTECTION CASING HEATER MP1A RAP1 RAP2 DATA 19/11/2013 NRL 500 - 550H CIRCUITO AUSILIARIO DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Auxiliary circuit REV. MODIFICA...
  • Page 5 500mA INTERRUTTORE SWITCH TRASFORMATORE TRANSFORMER DATA 19/11/2013 NRL 500 - 550H CIRCUITO AUSILIARIO DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Auxiliary circuit REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
  • Page 6 RAP2 IC/F MTV2 MTV1 TGP1 TGP2 Comando a distanza Remote control MTC1 MTC1A MTC2 MP1A DATA 19/11/2013 NRL 500 - 550H COLLEGAMENTO SICUREZZE DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Safety connection REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV.
  • Page 7 PUNP CONTROL VSB1 VSB2 VIC1 VIC2 VSL1 VSL2 Antigelo tubi Antigelo ev Pipe antifreese Antifreese EV CC1A DATA 19/11/2013 NRL 500 - 550H COLLEGAMENTO CARICHI DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Load connection REV. MODIFICA DATA...
  • Page 8 4/20mA 4/20mA TAP2 TBP2 TAP1 TBP1 SEV1 SEV2 MAX 230V 1A LINEA MAX 230V 1A LINE DATA 19/11/2013 NRL 500 - 550H COLLEGAMENTO SENSORI DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Analogic connection REV. MODIFICA DATA...
  • Page 9 VE' MA' GI' 50VA STEPPER MOTOR OPEN A OPEN B CLOSE A CLOSE B Tx/Rx COMPONENTE OPZIONALE OPTIONAL COMPONENT DATA 19/11/2013 NRL 500 - 550H VALVOLA ELETTRONICA DISEGN. AERMEC S.P.A. Crivellaro DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Electronic valve REV.
  • Page 10 ESP1 ESP2 M1SE2 M2SE2 M3SE2 ESP2 P.C. ID10 ID11 ID12 ID13 DATA 19/11/2013 NRL 500 - 550H SCHEDA GR3 + 2 ESPANSIONI DISEGN. AERMEC S.P.A. Crivellaro GR3-001 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Board GR3 + 2 expansions REV.
  • Page 11 MTV1 MTV1 MTV1 MORSETTIERA QUADRO TERMINAL BOARD DATA 19/11/2013 NRL 500 - 550H RIEPILOGO MORSETTI DISEGN. AERMEC S.P.A. Crivellaro M1-001 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Summary terminals REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
  • Page 12 MORSETTIERA QUADRO TERMINAL BOARD DATA 19/11/2013 NRL 500 - 550H RIEPILOGO MORSETTI DISEGN. AERMEC S.P.A. Crivellaro M3-001 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Summary terminals REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
  • Page 13 MP1A MP1A RC1A RC1A TGP1 TGP1 TGP2 TGP2 VIC1 VIC1 VIC2 MORSETTIERA QUADRO TERMINAL BOARD DATA 19/11/2013 NRL 500 - 550H RIEPILOGO MORSETTI DISEGN. AERMEC S.P.A. Crivellaro M-001 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Summary terminals REV. MODIFICA DATA...
  • Page 14 VIC2 MORSETTIERA QUADRO TERMINAL BOARD DATA 19/11/2013 NRL 500 - 550H RIEPILOGO MORSETTI DISEGN. AERMEC S.P.A. Crivellaro M-002 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY Summary terminals REV. MODIFICA DATA DISEGNATO VERIFICATO APPROV. De Togni...
  • Page 15 Elemento riscaldante 040112 E... Heating element Filtro di rete 101605-A Emi filter Fusibile 072101 FU... Fuse DATA 19/11/2013 NRL 500 - 550H RIEPILOGO SIMBOLI SCHEMA DISEGN. AERMEC S.P.A. Crivellaro RS-1 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY SYMBOLS SUMMARY REV.
  • Page 16 040104-NTC Variable resistance NTC Resistore variabile PTC 040104-PTC Variable resistance PTC Trasduttore di pressione 3 fili 040104-TRASD Pressure trasducer 3 wires DATA 19/11/2013 NRL 500 - 550H RIEPILOGO SIMBOLI SCHEMA DISEGN. AERMEC S.P.A. Crivellaro RS-2 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY SYMBOLS SUMMARY REV.
  • Page 17 Contatto NC sensibile alla pressione 070701PC SP... NC contact actuated by pressure Fine corsa NA con camma 070801CAM SQ... NO limit-switch with cam DATA 19/11/2013 NRL 500 - 550H RIEPILOGO SIMBOLI SCHEMA DISEGN. AERMEC S.P.A. Crivellaro RS-3 DATA 19/11/2013 FOGL. 4956269_00...
  • Page 18 OPEN A OPEN B CLOSE A CLOSE B Tx/Rx 0.71x Elettrovalvola chiusa 071502B YV... Closed solenoid valve DATA 19/11/2013 NRL 500 - 550H RIEPILOGO SIMBOLI SCHEMA DISEGN. AERMEC S.P.A. Crivellaro RS-4 DATA 19/11/2013 FOGL. 4956269_00 BEVILACQUA (VERONA) ITALY SYMBOLS SUMMARY REV.
  • Page 19 LEGENDA PER SERIE NRA-NRC-NRL 275 - 3600 10/07/13 ITALIANO ENGLISH FRANCAIS DEUTSCH ALLARME ESTERNO REMOTE ALARM ALARME EXTERIEUR FERNSTOERMELDUNG PRESSOSTATO DI ALTA HIGH PRESSURE CONTROL PRESSOSTAT HAUTE PRESSION HOCHDRUCKPRESSOSTAT PRESSOSTATO DI BASSA LOW PRESSURE CONTROL PRESSOSTAT BASSE PRESSION NIEDERDRUCKPRESSOSTAT INTERRUTTORE CALDO / FREDDO SWITCH HOT-COLD INTERRUPTEUR CHAUD - FROID UMSCHALTER - WARM/KALT...
  • Page 20 SONDA INGRESSO ACQUA WATER INLET PROBE SONDE ENTREE EAU FUEHLER – WASSEREINTRITT SONDA LIQUIDO LIQUID PROBE SONDE LIQUIDE FÜHLER- FLÜSSIGKEIT SONDA RITORNO UTENZE BACK UTILITIES PROBE SONDE RETOUR DE SERVICES ZURÜCK EXTRAS PROBE SONDA USCITA RECUPERO RECOVERY OUTLET PROBE SONDE SORTIE RECUPERATION FUEHLER –...

Ce manuel est également adapté pour:

Nrl 500h