Télécharger Imprimer la page

AERMEC NRL 500 Schéma D'installation page 3

Schema elettrico

Publicité

1
1.8
L3
1.8
L2
A
1.8
L1
SEZ. 3
B
C
MTV1
D
E
F
REV.
MODIFICA
DATA
1
2
3
F4
16A
U
V
W
MTV1
NA NC
1
3
5
1
5.3
MTV2
I>
I>
I>
I>
2
4
6
2
U
V
W
U
M
MV
MVA
3
VENTILATORE
Per il N° esatto dei ventilatori consultare documentazione tecnica
FAN
For the exact N ° of fans refer to the technical documentation
DATA
19/11/2013
DISEGN.
Crivellaro
DATA
19/11/2013
DISEGNATO
VERIFICATO
APPROV.
De Togni
2
3
4
5
L3
L2
L1
SEZ. 4
F1
1A
A1
RCS
11
MTV2
NA NC
3
5
5.3
I>
I>
4
6
V
W
M
3
AERMEC S.P.A.
BEVILACQUA (VERONA) ITALY
4
5
6
A2
A3
V
14
RCS
NA NC
5.4
POTENZA
POWER
6
7
8
SEZ. 5
F2
6A
0
208
TR1
1000VA
0
230
34
1
F3
FR
4A
1A
2
2A
1
2
2A
3.1
3.1
3.1
NRL 500 - 550H
=
+
2
FOGL.
4956269_00
3
DI
3
7
8
A
B
C
D
E
F

Publicité

loading

Ce manuel est également adapté pour:

Nrl 500h