Installation and Operating Instructions
EN
Product name
AIR1-JVK XH 8500/RH 9500
AIR1-JVK RH 12000
AIR1-JVK RH 15000
CHAPTER 2
INSTALLATION AND
COMMISSIONING
m
WARNING
m
DANGER
Multi-leaf damper AIR1-JVK
Weight
Runtime (open/
(kg)
closed)
(s)
8.6
40...75
10
40...75
13
40...75
Dimensions Multi-leaf damper for AIR1 XC units
Type
AIR1-JVK XC 500
Art.-Nr. Type
AIR1-JVK XC 700
AIR1-JVK XC 1400
05421 AIR1-JVK XC 500
AIR1-JVK XC 2200
05841 AIR1-JVK XC 700
AIR1-JVK XC 3200
05856 AIR1-JVK XC 1400
06000 AIR1-JVK XC 2200
2 .0

General installation instructions

2 .0 .1 Receipt

06003 AIR1-JVK XC 3200
Please check delivery immediately on receipt for accuracy and damage. If damaged, please notify the carrier immedia-
tely. In case of delayed notification, any possible claim may be void.

2 .0 .2 Storage

When storing for a prolonged time, the following steps are to be taken to avoid damaging influences:
Protection by dry, airtight and dust-proof packaging (plastic bag with desiccant and humidity indicators). The storage
place must be waterproof, vibration-free and free of temperature variations. Damages due to improper transportation,
storage or commissioning must be verified and are not liable for warranty.

2 .0 .3 Disassembly and re-assembly

m
Risk of personal injury and material damage!
The disassembly and re-assembly of the unit are not part of routine maintenance.
– The disassembly and re-assembly of the unit may only be carried out by a qualified specialist.

2 .0 .4 Disposal

m
Danger to life due to electric shock
An electric shock can result in death or serious injury.
– Ensure that the unit is voltage-free and isolated from the mains power supply. Ground and short circuit the unit, shield
neighbouring live components.
All components must be disposed of in an environmentally-friendly manner in accordance with the local codes, practi-
ces and environmental regulations.
Ambient
Power max .
temp . (°C)
(W)
-30 - 50
2.5
-30 - 50
2.5
-30 - 50
2.5
R
T
A
D
A
B
D
R
340
185
430
320
A
440
235
523
420
540
285
623
520
340 185 430 320 170 300 100
540
335
623
520
440 235 523 420 220 400 150
740
435
823
720
540 285 623 520 270 500 200
540 335 623 520 320 500 250
740 435 823 720 420 700 350
!
3
Operating
Protection
voltage (W)
class (IP)
24 DC
24 DC
24 DC
76
S
T
U
Maße (mm)
170
300
100
B
D
R
S
220
400
150
270
500
200
320
500
250
420
700
350
Actuator type
Spring return
Spring return
Spring return
Fig .1