Battery Status - Cembre B131-UC Notice D'utilisation Et Entretien

Table des Matières

Publicité

ENGLISH

3.7) Battery status

(Ref. to Fig. 1)
After releasing the operation push-button, the residual battery capacity is automatically displayed,
for 5 seconds (25). The number of Led's illuminated indicates the residual capacity:
8 led's illuminated: fully charged
4 led's illuminated: 50 % capacity
1 led illuminated:
minimum charge
When replacing the battery (19) press the two points marked with the word "PUSH" at the same
time, remove the fl at battery from its housing and insert the new one.
3.8) Power from an external source
Using the integral socket (23) the tool can operate from an external power supply (min. 20A)
or vehicle battery.
Using the special connection cable type ESC600, supplied as an optional accessory, proceed
as follows:
– Make sure the feed voltage is between 12 and 14,4 Volt DC.
– Connect the end with the spring grips to the external supply making sure to comply with the
polarity: the red grips to the positive pole (+), the black to the negative pole (–).
– Remove the cap (22) and connect the other end of the connection cable (53) to the socket
(23) of the tool; tighten the connector (52) by turning the ring nut clockwise until it locks.
– When the work is fi nished, disconnect the connection cable (53) and replace the protective
cap (22).
Should the poles be accidentally reversed, the tool will not be damaged but will operate using
only the integral battery (19). For rectifi cation, reverse the polarity of the grips.
W
HEN OPERATING USING POWER SUPPLY FROM AN EXTERNAL SOURCE
CIRCUIT THE METAL CONTACTS INSIDE THE BATTERY HOUSING
,
(19)
BATTERY
IN ITS HOUSING
IT WILL SUPPLY POWER IN PARALLEL WITH THE EXTERNAL
.
SOURCE
4. WARNING
Before starting work on electrical equipment, please ensure that either there are no live parts in
the immediate working area or that precautions are taken for working near live parts in accord-
ance with EN50110-1.
D
O NOT USE THIS TOOL ON OR NEAR ENERGIZED CONDUCTORS WITHOUT PROPER
PERSONAL PROTECTIVE EQUIPMENT
.
IN SEVERE INJURY OR DEATH
T
HE TOOL IS UNSUITABLE FOR CONTINUOUS USE AND SHOULD BE ALLOWED TO COOL
DOWN FOLLOWING UNINTERRUPTED
EXHAUSTED A FULLY CHARGED BATTERY IN ONE SESSION
.
MENT FOR A FEW MINUTES
O
BSERVE RECOMMENDED REST PERIODS ALSO WHEN USING AN EXTERNAL POWER SUPPLY
P
ROTECT THE TOOL FROM RAIN AND MOISTURE
. E
-
BATTERY
LECTRO
HYDRAULIC TOOLS SHOULD NOT BE OPERATED IN POURING RAIN
.
OR UNDER WATER
(Ref. to Fig. 7)
,
NEVER SHORT
,
WE ADVISE LEAVING THE
.
FAILURE TO OBSERVE THIS WARNING COULD RESULT
,
;
SUCCESSIVE OPERATIONS
FOR INSTANCE
,
DELAY BATTERY REPLACE
. W
ATER WILL DAMAGE THE TOOL AND
,
HAVING
-
.
7
40

Publicité

Table des Matières
loading

Table des Matières