Cleaning The Air System; Faults / Trouble-Shooting; Decommissioning/Disposal - Dimplex LA 17PS Instructions D'installation Et D'utilisation

Table des Matières

Publicité

8.3 Cleaning the Air System

Evaporator, ventilator and condensate outflow should be cleaned
of contamination (leaves, twigs, etc.) before each new heating
period.
Do this by opening the front of the heat pump. The bottom should
be opened first followed by the top.
ATTENTION!
Before opening the device, ensure that all circuits are isolated from the
power supply.
Remove and rehang the side panel assemblies as described in
Chapter 4.
To prevent the evaporator and the condensate tray from being
damaged, do not use hard or sharp objects for cleaning.
ATTENTION!
The refrigerating circuit may not be damaged in any way.
Inflammable refrigerant could leak out if the refrigerating circuit is
damaged. Ignition sources and open flames must be avoided
when carrying out any work on the device.
Under extreme weather conditions (e.g. snow drifts), ice may
form on the air intake and exhaust air outlet grids. If this happens,
the ice must be removed in the vicinity of the air intake and ex-
haust air outlet grids to ensure that the minimum air flow rate is
maintained.
9
Faults / Trouble-
Shooting
This heat pump is a quality product and is designed for trouble-
free operation. In the event that a fault should occur, it will be in-
dicated on the heat pump manager display. Simply consult the
Faults and Trouble-shooting page in the operating instructions of
the heat pump manager. If you cannot correct the fault yourself,
please contact your after-sales service technician.
ATTENTION!
Any work on the heat pump may only be performed by authorised and
qualified after-sales service technicians.
Anyone carrying out work on the refrigerating circuit must be cer-
tified to safely handle inflammable refrigerants or be supervised
by a person having such certification.
10 Decommissioning/
Disposal
Before removing the heat pump, disconnect it from the power
source and close all valves. Observe all environmentally-relevant
requirements regarding the recovery, recycling and disposal of
materials and components in accordance with all applicable
standards. Particular attention should be paid to the proper dis-
posal of refrigerants and refrigeration oils.
www.dimplex.de
452159.66.04 · FD 9202
LA 17PS - LA 26PS
EN-9

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

La 22psLa 26ps

Table des Matières