Open the device
• Ensure that the power supply is switched off.
• Remove screws (1) of the housing upper section (2).
• Remove housing upper section (2).
• Remove screws (3) of front panel (4) and fold down front
panel (4).
• Disconnect power supply line
• Remove screws (5) holding the device to the wall.

6. Install protective roof

Device damage due to unsuitable ambient condi-
tions – life-threatening danger due to electric shock!
• Use the device only under suitable ambient conditions,
as the risk of electric shock can increase due to a
damaged device.
• Observe the installation instructions for the charging
station.
4
WARNING
Unsuitable substrate for the wall mounting
Use of the protective roof with an unsuitable wall
substrate can result in damage to the device, thus
increasing the risk of electric shock.
• Select a suitable substrate for attaching the wall
mounting.
Drill the fixing holes
Suitable fastening elements (e.g. screws and dowels) must
be used for installation of the device.
Select fastening elements with sufficient load-bearing capa-
city for installation of the device (screw diameter 8 mm).
Observe the information on the device dimensions and
device weight.

See AMTRON
Installation Instructions
®
• Observe the manufacturer's information regarding the
fastening elements.
• Drill the fixing holes and insert the dowels.