| 10 | BEA 550 | Operation
4.
Operation
!
Only transport the BEA 070 and BEA 060 in an
upright position. If the BEA 070 and BEA 060
are tilted during transportation, condensate may
escape and damage the measurement chamber.
4.1
Commissioning
1. Remove the packaging from all components
supplied.
2. Attach order number adhesive label BEA 550 on the
front of the unit near the nameplate, in the case of
BEA 060 and BEA 070, and above the nameplate in
the case of BEA 030.
3. Connect BEA 060, BEA 070 to voltage using the
power supply cable.
4. Connect BEA.030 to voltage using the power
supply unit.
5. Connect sensors, exhaust gas sampling probes and
adapter cables in the slots provided at BEA 030,
BEA 060 and BEA 070 (see respective operating
instructions).
i
The USB connecting cables are only needed if
BEA 030, BEA 060 and BEA 070 are not configured
via a Bluetooth connection.
4.2

Switching on/off

!
To avoid the formation of condensation, allow
BEA 060 and BEA 070 to adjust to the ambient
temperature before switching them on!
!
Prior to commissioning, make sure the mains
voltage system voltage matches the set voltages
of BEA 030, BEA 060 and BEA 070. If the devices
are operated outdoors, it is advisable to use a
voltage source which is protected by a ground fault
interrupter. The BEA 550 must only be operated in
dry conditions.
|
1 689 989 178
2022-07-24
4.3
Software installation
4.3.1
SystemSoft BEA-PC
1. Close all open applications.
2. Insert "SystemSoft BEA-PC" DVD in DVD drive.
3. Start "Windows Explorer".
4. Start 'D:\RBSETUP.EXE' (D = DVD drive letter).
� BEA setup is starting.
5. Confirm with <Continue>.
6. Read and follow the instructions on screen.
7. Re-start the computer to complete the installation.
"
SystemSoft BEA-PC is installed.
4.3.2
Device interface settings
The device interfaces of the device types must be set
after installing and starting SystemSoft BEA-PC.
1. Select "Start >> All programs >> Bosch >>
Diagnostics >> Central Device Communication"
or click on "
" in the task bar with the left mouse
button.
� CDC - Central Device Communication is opened.
2. Select "Settings >> Device interfaces".
i
Pressing <F1> opens the Online Help. The most
important information on interface settings is
displayed here. KTS modules (special accessory)
must be configured using <F2> DDC (Diagnostic
Device Configuration).
3. Configure all devices (USB or Bluetooth).
� BEA 550 is ready for operation.
4. Start SystemSoft BEA-PC.