Use this product for its intended
use
The stationary used oil fired hot air heater
has been designed for heating of workshops
at mechanization companies, heating and
frost protection of halls, transit sheds and
warehouses and heating of garage
workshops.
Caution
If the heater will be installed indoors,
make sure that there is proper
ventilation in the room. Make sure the
flue gas can only flow to an outside
source separate from the room.
1.4

General instructions

Warning
Make sure that the heater is
properly installed, adjusted and
maintained.
For all service and adjustments
contact qualified, competent and
authorized persons.
Do not make any modifications to
the heater without the prior
written consent of the
manufacturer.
Make sure to always follow the
local standards and guidelines as
well as the local requirements,
concerning environmental
quality, fuel, fire and electrical
safety.
Read this manual carefully
before using the heater.
Keep this document with the
heater.
Follow the described procedures.
Never lean against the heater.
6
All manuals and user guides at all-guides.com
1.5
40.020.943 - rev. 04 - 2011
Warning
Do not create a fire hazard by
storing or using highly
inflammable materials near the
heater. Keep these materials at
adequate distance from the
heater:
-
top and sides 6 inch (150
mm)
-
front 35 inch (890 mm)
-
back and flue 18 inch (460
mm)
Make sure there is enough air for
proper combustion.
Make sure that the convector
heater has cooled down
sufficiently and that the plug has
been removed from the socket
before carrying out any repair or
maintenance work.
Additional safety
Warning
Connect the heater only to a
120 V / 60 Hz power supply.
Replace fuses only with identical
spares.
The heater must be grounded.
AT 400 - 500-US series