6.4
Factory Set Parameter
When the function "reset to factory set parameter" is activated, individually set information is lost
and overwritten by factory set values.
This does not apply for the operating hour values and the threshold values for automatic operation.
Return to factory settings:
⇒ Extraction off
and
Press button (46, 48, Fig. 2) and keep pressed.
⇒ Extraction on
and
Press button (46, 48, Fig. 2) and keep pressed.
♦ An audible signal will confirm the factory set parameter is saved and the display will indicate „rES".
Factory set parameter:
Function / Feature
Suction level
Turbo function
Operating time until the dust drawer is
emptied
Self diagnosis
(after switching on)
Acoustic signal
Favorite status
Switch off threshold suction turbine
6.5
Spare Parts
You can find components subject to wear and the spare parts on the spare part list in the
internet at www.renfert.com/p918.
Enter the following item number: 29330000
The components excluded from the warranty (such as consumables or parts subject to wear
and tear) are marked on the spare part list.
Serial numbers, manufacture date and device type can be found on the device identification plate.
7. Troubleshooting
Error
Extractor stops sudden-
ly for no apparent rea-
son and a error code is
indicated in the display.
The suction perfor-
mance is inadequate at
one suction point.
Dust bag over full.
The dust drawer full sig-
nal lights up, although
the drawer is not yet full.
Suction hose cannot be
closed by pressing the
suction hose button.
Mode
Possible Cause
• An error has been detected.
• The set suction level is too low.
• The suction tube is either blocked or
has a leak.
• The set value for the dust drawer fill
level is too high.
• The dust drawer was removed for lon-
ger than 15 seconds without emptying.
• The set value for the dust drawer fill
level is too low.
• An electrical appliance which is
connected to the suction hose is still in
operation.
Adjustment Range
Single / multi use
1 - 4
On / Off
1 - 5
On / Off
On / Off
A, B, C, D,
0 - 30 Sec.
• See table "Error Codes"
If the instructions are of no help to you, or the error
code is not listed:
- Make a note of the error code.
- Send the device in for repair.
- Inform the repair service which error code was not-
ed.
• Select a higher suction level.
• Check the suction tube.
• Please observe the notes in section 4.5.
• Set a smaller value (see section 5.6.3).
• If you remove the dust drawer, please always empty it.
• Set a higher value for the fill level (section 5.6.3).
• Switch the connected electrical appliance off.
- 21 -
Factory Parameter
Multi use
2
Off
3
On
On
Not allocated
3 Sec.
Corrective Action