Charging The Battery Life Through The Generator; Charging And Supplying The Refrigeration Unit Through The Generator; Seep Mode; Auto Off - Carrier BATTERY LIFE Manuel

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
GB
FR
DE
ES
IT
5.6. CHARGING THE BATTERY LIFE THROUGH THE GENER-
ATOR
Whenever the generator is producing energy:
• The system will start charging automatically and the
ON light will be either blinking or lit in white.
• The autonomy indicators will blink during charge
representing the battery level.
5.7. CHARGING AND SUPPLYING THE REFRIGERATION
UNIT THROUGH THE GENERATOR
Whenever the generator is producing energy while
the refrigeration unit is operating at the same time:
• The system will start charging automatically and the
ON light will be either blinking or lit in white.
• The autonomy indicators will blink during charge
representing the battery level.
• In the display will activate the electric motor indicator,
meaning that the Refrigeration unit is operating in
electric mode.

5.8. SEEP MODE

Telematics can shut down the Battery life (disable service discon-
nect) to save battery
The sleep mode can be entered when following condition occur:
• 72h without load.
• 30min without battery information.
e.g. service disconnect is manually pressed.
On trailers, after system is turned OFF the first time, it will not
turn on again.
It will be necessary to manually turn ON the telematics.
It will be necessary to manually turn ON the telematics.

5.9. AUTO OFF

Telematics automatically turn OFF the Battery life after 3 hours without
detecting load (remote shows OFF).
• Plugging the grid also resets the 3h time, and the system will not go to
sleep while the plug is connected.
• However, even is the plug is connected for 2h30, with no button is
pressed and then the plug is removed:
if the "battery life" no detects load after 30 minutes, the system
will go to off as well (totaling 3 hours)
On trailers, after Battery life is turned OFF the first time, it will
not turn ON again. It will be necessary to manually turn ON
the telematics.
62-61974-04
NL
DK

6. DRIVER TROUBLESHOOTING

Carrier Transicold produces Battery life units' within the highest
level of quality and reliability. However, if the Battery life unit isn't
handled correctly, it shows certain alerts to guide the user to re-
store its normal operation.
Symptom
Possible cause
Refrigeration unit
tried to start before
the Battery life unit is
ready.
Battery life unit is in
sleep mode / critically
discharged.
Refrigeration unit de-
tects "NO POWER"
Fuse in FUBO (Fuse
Box) broken.
Defect on cabling /
connectors.
Battery life unit
is completely dis-
charged.
Refrigeration unit in
electric stops before
reaching setpoint
Device failed.
Fuse in FUBO (Fuse
Refrigeration unit
Box) broken.
does not start from
Battery life unit no
power grid
Issue on refrigeration
unit
If the problem you are experiencing with the unit is not listed in this
section, please contact your Carrier Transicold service partner.
6.1. ALARM SIGNALS - SUPPLY REFRIGERATION UNIT
USING BATTERY LIFE UNIT
If ON is yellow and Battery life unit is not
starting
1. Press and rotate the Service Disconnect;
2. Press the green button until ON is white, restarting
Battery life unit.
If the alarm persists please contact your
Carrier Transicold service partner
If the ON and OFF buttons are grey
1. Press and rotate the Service Disconnect;
2. Press the green button until ON is white, restarting
Battery life unit.
Possible solution
Shutdown Refrigera-
tion unit and start Bat-
tery life unit before
the refrigeration unit.
Connect to the power
grid, turn service dis-
connect OFF and ON.
Follow instructions in
Alarm Signal section.
Press the service dis-
connect and discon-
nect from power grid.
Measure continuity
of all fuses in FUBO.
Replace all broken
fuses.
Open Motor and Grid/
Gen power cables
connectors on Battery
life unit back and vi-
sually inspect for de-
fects.
Charge Battery life
unit before trying
again.
Check if "fail" is active
on display. Follow in-
structions in Alarm
Signal section.
Press service discon-
nect and disconnect
from grid. Measure
continuity of all fuses
in FUBO. Replace all
broken fuses.
Check Service Manu-
al of refrigeration unit.
6

Publicité

Table des Matières
loading