Siemens SITRANS F MAG 8000 Instructions De Service page 46

Compteur d'eau électromagnétique
Masquer les pouces Voir aussi pour SITRANS F MAG 8000:
Table des Matières

Publicité

MAG 8000 & MAG 8000 CT
46
Communication
1)
Battery power supply
12-24 V AC/DC power supply
115/230 V AC mains power
supply
Input cable for
12-24 V AC/DC and
115/230 V AC power supply
1)
Lithium batteries are subject to special transportation regulations accord-ing to United Nations
"Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required
to observe these regu-lations. This may influence both transport time and costs.
SFIDK.PS.026.D10.04
IrDA : Interface de communication infrarouge intégrée avec
protocole MODBUS RTU (standard)
Modules additionnels :
Interface série RS 232 avec MODBUS RTU (Rx/Tx/GND), type
point-à-point avec 15 m de câble max.
Interface série RS 485 avec MODBUS RTU (+/-/GND), type
multipoint avec un maximum de 32 appareils et 1000 m de câble
Le protocole MODBUS RTU est un protocole ouvert (informations
détaillées disponibles sur demande)
Vitesse de transmission série 1200, 2400, 4800, 9600, 19200,
38400 bauds
Auto detection of power source with displayed symbol for remaining
power. In battery mode, excitation frequency is manually selected
Internal battery pack: 2 D-Cell 3.6 V / 33 Ah
External battery pack: 4 D-Cell 3.6 V / 66 Ah
Input voltage range: 12-24 V AC/DC (10-32 V AC/DC)
Power consumption during line: 2 VA
Isolation: Class II
Fuse: 1000 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
Input voltage range: 115/230 V AC, +15% to -20%, 50-60 Hz
Power consumption during mains: 2 VA
Isolation: Class II
Fuse: 250 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
Factory mounted PUR cable with 2 x 1 mm
(brown, blue), length = 3 m
Resistant to sunlight and water
Outer diameter 7 mm
Rated voltage (V AC) 300/500 V AC
Testing voltage (V AC) 2000 V AC
Temperature range (°C):
Minumum bending radius 28 mm, (fixed installation)
Maximum pulling force 200 N
Output: As battery connector - female
Backup battery: As battery connector - male
2
Fixed laying -40 to +90 °C
Flexible application -30 to +80 °C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sitrans f mag 8000 ct

Table des Matières