Burner nozzle replacement
1. Remove bottom of the appliance.
2. Unscrew the nozzle and replace it with the one suited for the gas used.
Table 4: nozzle dimensions
Supply gas type
G20 (20 mbar)
G30 (28-30 mbar)
G30 (50 mbar)
Heat power adjustment to minimum
– METHANE GAS powered appliance
1. Turn on the appliance and run it at maxi-
mum power for about 10 minutes.
2. Rotate the burner control knob to the min-
imum power position and pull it out.
3. Turn the minimum adjustment screw (D)
clockwise or counter-clockwise to achieve
a stable flame.
4. Rotate the burner control knob to turn it
off.
5. Repeat minimum adjustment if the appli-
ance is equipped with another burner.
6. Seal the adjustment screw with paint and repeat the operation on the other burner (if in-
stalled).
7. Reassemble the burner knob and the other burner knob (if installed).
– LIQUID PROPANE GAS powered appliance (LPG)
1. Remove the knob.
2. Fully tighten the minimum adjustment screw (D).
3. Pull out the knob and tighten the second burner screw (if installed).
4. Turn on the appliance and make sure the flame is stable.
5. Turn off the appliance. Seal the adjustment screw with paint and repeat the operation on
the other burner (if installed).
6. Reassemble the burner knob and the other burner knob (if installed).
FIMAR-RUSSIA.RU +7 495 989 1055
FRY1/LM/LMC - FRY1/RM/RMC
Burner nozzle diameter
1,35 mm
0,93 mm
0,77 mm
- 17 -
GAS SUPPLY
FRY2/LM/LMC - FRY2/LRM/LRMC
Burner nozzle diameter
2 x 1,35 mm
2 x 0,93 mm
2 x 0,77 mm