  • Page 1 CH-9101 Herisau/Suisse E-Mail info@metrohm.com Internet www.metrohm.com 795 KFT Titrino Version de programme 5.795.0010 Mode d’emploi 8.795.1002 11.2001 / pkl...
  • Page 3: Table Des Matières

    3.3.3 Que faire, si la transmission des données ne fonctionne pas? ......95 4 Messages d'erreur, dérangements ................. 97 4.1 Messages d'erreur et messages spéciaux ............... 97 4.2 Diagnostic....................... 100 4.2.1 Généralités ....................... 100 4.2.2 Procédé......................100 4.2.3 Appareillage nécessaire................... 101 4.2.4 Déroulement du diagnostic................101 795 KFT Titrino...
  • Page 4 6.5. Garantie et conformité................... 140 6.5.1 Garantie ......................140 6.5.2 Attestation de conformité UE................141 6.5.3 Certificat de conformité et de validation du systéme ........142 6.6 Programme de livraison et numéros de commande..........143 Index ...........................147 795 KFT Titrino...
  • Page 5: Introduction

    1 Introduction 1.1 Description de l'appareil Le 795 KFT Titrino est un titreur pour la détermination de la teneur en eau rapide et pré- cise avec grand écran LCD. Les courbes de titrage sont représentées en temps réel. Les déroulements de titrage sont programmables au choix et tous les modes d'opération se laissent combiner pour des séquences d'analyse étendues.
  • Page 6: Eléments De Commande

    Introduction 1.2 Eléments de commande Face avant de l'appareil: 795 KFT Titrino...
  • Page 7 Témoin allumé si le récipient est condi- tionné "STATISTICS" Témoin allumé si la fonction "statistique" est ac- tivée (calcul de la moyenne et écart type). "SILO" Témoin allumé si la mémoire silo est connectée (pour les données d'échantillons). 795 KFT Titrino...
  • Page 8: Face Arrière De L'appareil

    Introduction Face arrière de l'appareil: 795 KFT Titrino...
  • Page 9: Branchement Au Secteur

    Branchement au secteur Si le réseau est fortement perturbé par des HF, le Titrino doit être bran- ché via un filtre de réseau, tel que le modèle Metrohm 615. Branchement de l'agitateur Agitateur magnétique 728, Agitateur à tige 802, Poste Ti 703 ou Poste Ti 727 Tension d'alimentation: 10 VDC (I ≤...
  • Page 10: Opération Manuelle

    Efface ou introduit des valeurs spéciales ENTER Adopte les valeurs STOP Arrête les méthodes QUIT Abandonne les consultations et les pauses START Démarre les méthodes Les fonctions tierces (plan d'inscription supérieur) des touches servent à l'introduction des formules, voir page 25. 795 KFT Titrino...
  • Page 11: Principe De L'introduction Des Données

    Si vous appuyez une deuxième fois sur <QUIT>, >Variables communes vous abandonnez le groupe de consultations “configuration”. • Pour faire rouler l'affichage, ceci est indiqué par "↓" resp. "↑" à droite, en bas respectivement en haut de l'affichage. 795 KFT Titrino...
  • Page 12: Introduction Des Textes

    3. Vous pouvez effacer les caractères les uns après les autres avec <CLEAR> ou ajouter des caractères à votre texte. 4. Lorsque vous avez fini, abandonnez l'introduc- tion du texte avec <QUIT> et adoptez le nou- veau nom avec <ENTER>. 795 KFT Titrino...
  • Page 13: Configuration, Touche

    Titrino. Lorsque le contrôle est activé, le message "prochain service" apparaît. Le message disparaît avec <CLEAR>. Lorsque "oui" a été entré: Date du prochain service (AAAA-MM-JJ) prochain serv.AAAA-MM-JJ Impression du rapport test de système (oui, non) rapp.test système: 795 KFT Titrino...
  • Page 14: Réglages Pour Les Appareils Périphériques

    A la prise Remote pour clavier ordinateur et lecteur de codes bandes, voir page 118. Lorsque "oui" est réglé: Type de clavier ordinateur (US, deutsch, français, clavier: espanol, schweiz.) Le clavier ordinateur facilite l’entrée de données, voir page 119. 795 KFT Titrino...
  • Page 15: Réglages Divers

    En gras: les résultats calculés sont indiqués en gras. Standard: l'information complète est indiquée, par exemple résultats, EP's, messages etc. Désignation individuelle d’appareils (jusqu'à 8 adresse caractères ASCII) Imprimé dans le rapport des résultats, voir page 32. Indication de la version de programme programme 795.0010 795 KFT Titrino...
  • Page 16: Valeurs Des Variables Communes

    "oui" signifie la fonction correspondante n'est plus accessible. <configuration>: <parameters>: La touche correspondante n'est plus accessible. <smpl data>: Charger méthode: La fonction correspondante de la mémoire des Mémoriser méthode: méthodes du Titrino n'est plus accessible. Eliminer méthode: 795 KFT Titrino...
  • Page 17 1 est la largeur la plus grande. Avec 1, il est donc possible qu’un peu d'écriture sur le bord droit soit perdu. Longueur (0.01...1.00) longueur 0.05 Axe du temps: Longueur de la courbe 0.01 100 cm 10 cm 2 cm 1 cm 795 KFT Titrino...
  • Page 18: Touche

    Upol) sont choisies à l’aide de la touche <←> ou <→> et confirmées avec <ENTER>. Le mode KFT est autant que possible muni des paramètres standards et est prêt à l’emploi après seulement de minimes modifications. 795 KFT Titrino...
  • Page 19: Paramètres, Touche

    Plage de régulation (la gamme d'introduction dépend plage régul. 100 mV de la quantité de mesure): **titr. Ipol: 1...2000 mV Upol: 0.1...200.0 µ Hors de la plage de régulation, le dosage est continu, voir aussi page 21. 795 KFT Titrino...
  • Page 20 être interrompue par <QUIT>. Type de volume de départ (non, abs., rel.) V départ: "non": Pas de volume de départ cond. "abs": Volume de départ absolu en mL "rel.": Volume de départ relatif à la prise d'essai 795 KFT Titrino...
  • Page 21 Intervalle de temps pour l’inscription du point de me- cond. sure dans la liste des points de mesure. Conditions d'arrêt du titrage >Conditions d'arrêt Au cas où l'arrêt ne s'effectue pas normalement lorsque le point final a été atteint. 795 KFT Titrino...
  • Page 22: Présélections Pour Le Déroulement Du Titrage

    Consultation de la prise d'essai après le démarrage du demande p.d'essai: titrage (val, unité, tous, non) cond. Avec "tous" la valeur, puis l’unité sont consultées. 795 KFT Titrino...
  • Page 23 Mettre sur "non", lorsqu’aucun Four n’est connecté ou lorsque le Four n’est pas relié au Titrino via RS232. Emission d'une impulsion sur la ligne de commande activation impuls: "Activate" (L6, pin 1) de la douille "Remote" (premier, cond. tous, cond., non). Voir page 126. 795 KFT Titrino...
  • Page 24 (Agitateur OFF) L'agitateur est mis hors tension. Calculs Les calculs sont effectués. Les données sont sorties. Sortie des données Après le titrage, le récipient sera de nouveau conditionné. (Post-conditionnement) 795 KFT Titrino...
  • Page 25 également avec les mêmes paramètres. • Pour les titrages KF standards, nous recommandons le mode KFT Ipol avec les paramètres standards. • Avec Ipol, les courbes résultantes ont une pente relativement élevée; avec Upol, elles sont plus plates. 795 KFT Titrino...
  • Page 26 • Si des valeurs négatives sont choisies pour les divers paramètres, il faut que toutes les valeurs pour U ou I reçoivent également le signe négatif, afin de ne pas obtenir des combinaisons de valeurs insensées. • Pour le mode KFT Upol, les mêmes règles s'appliquent que pour KFT Ipol. 795 KFT Titrino...
  • Page 27: Introduction De L'échantillon

    Faites toujours attention à éviter, si possible totalement, la pénétration de l’humidité de l’air dans le vase de titrage. Si vous êtes obligé d’ouvrir la cellule de titrage KF à chaque dosage d’échantillon, définissez une valeur à blanc que vous introduisez dans le calcul du résultat (voir page 132). 795 KFT Titrino...
  • Page 28 • Dans le cas de réactifs à deux composants, il se peut de plus en plus longs que la capacité tampon du solvant soit épuisée. Changer le solvant. • Si la dérive augmente constamment en même temps: voir ci-dessus. 795 KFT Titrino...
  • Page 29: Calcul Des Résultats

    <CLEAR>, jusqu'à ce qu'il n'y ait plus que RSX à l'affichage. Adoptez par <ENTER>. Quand une formule est mémorisée par <ENTER>, le texte du résultat, le nombre des décimales après la virgule, l'unité du résultat et le réglage du contrôle de valeur limite sont consultés: 795 KFT Titrino...
  • Page 30 C26, 27 Moyennes des calculs silo, voir page 41ss C30...C39 Variables communes Valeur mesurée initiale de l’échantillon Volume final Durée de la détermination Dérive de volume au départ du titrage (pour KFT avec conditionnement) Température Volume de départ 795 KFT Titrino...
  • Page 31 Le rapport de calcul peut être imprimé à l’aide de la séquence de touches: <PRINT><←/→> (appuyez plusieurs fois sur les touches curseurs, jusqu'à ce que l'affichage indique "calc" <ENTER>). Exemple de rapport de calculation: Rapport de calculation 795 KFT Titrino 01103 795.0010 utilisateur date 2001-11-15...
  • Page 32: Calculs Statistiques

    Le tableau original est utilisé. Les résultats effacés sont réintégrés dans l'évaluation. "éliminer n": Elimination du résultat à indice n. "éliminer tout": Efface le tableau entier. Indice n du résultat à éliminer (1...20) éliminer Le résultat éliminé est extrait du calcul statistique. 795 KFT Titrino...
  • Page 33 • Lors d'un changement de méthode, l'ancien tableau statistique se trouve effacé pour faire place aux exigences de la nouvelle méthode. • Vous pouvez effacer d'anciens résultats, dont vous n'avez plus besoin, par "éliminer tout", (sous la touche <PARAM>, ">Statistique", "tab.rés."). 795 KFT Titrino...
  • Page 34: Variables Communes

    (CXX) et des moyennes (MNX). Les valeurs des variables communes restent valables C39= pour toutes les méthodes, jusqu'à ce qu'elles soient recouvertes ou effacées. On peut les consulter sous la touche <CONFIG>. Eliminer l'attribution: <CLEAR>+<ENTER> 795 KFT Titrino...
  • Page 35: Sorties Des Données

    Rapport de résultats court avec calculs et statistiques p. mes Liste des points mesurés courbe Courbe volume en fonction du temps cs cmpl Calculs silo complet cs court Calculs silo court calc Rapport avec formules et opérandes Form Feed à l'imprimante 795 KFT Titrino...
  • Page 36 Les rapports originaux sont clôturés par une ligne double ====, alors qu’après recalculation, les rapports sont clôturés par une ligne simple ----. Les sorties de rapport peuvent être interrompues par <QUIT>. Exemples de rapports: Rapport complet des résultats 795 KFT Titrino 01103 795.0010 Utilisateur (seulement si entré) utilisateur...
  • Page 37: Indication De La Courbe De Titrage

    Avec les touches <↑> et <↓>, vous pouvez vous déplacer le long de la courbe. A gauche de la courbe, dans la première ligne apparaît l'index du point mesu- ré; dans les lignes successives, les valeurs mesurées. 795 KFT Titrino...
  • Page 38: Noms D'utilisateur, Touche

    "vide". Effacer les noms d’utilisateur >Effacer Entrer le nom directement ou le choisir à l’aide des nom: touches curseurs <←> et <→>. Le nom désiré est effacé de la liste des noms d’utilisateur par la touche <ENTER>. 795 KFT Titrino...
  • Page 39: Mémoire Des Méthodes, Touche

    Si une méthode est déjà enregistrée sous la même identification, l'appareil vous demandera si l'ancienne méthode doit être recouverte par la nouvelle. Elle peut être recouverte avec <ENTER>; avec <QUIT> vous revenez à l'introduction d'identification de méthode. 795 KFT Titrino...
  • Page 40: Eliminer Une Méthode

    Vous pouvez faire imprimer le contenu de la mémoire de méthodes par la combinaison de touches: <PRINT><USER METH><ENTER> Documentez vos méthodes (par exemple rapport des paramètres, def-rapport et rapport C-fmla)! Si vous possédez un PC, faites un backup des méthodes régulièrement à l'aide du logiciel Metrohm, VESUV 6.6008.XXX. 795 KFT Titrino...
  • Page 41: Données D'échantillon Actuelles, Touche

    ± p.d'essai 1.0 g Introduction par le clavier, via balance ou via lecteur codes bandes. Unité de la prise d'essai (g, mg, mL, L, pc, aucune ou µ unité p.d'essai: jusqu'à 5 caractères ASCII) Sélection avec <←/→>. 795 KFT Titrino...
  • Page 42: Mémoire Silo Pour Les Données D'échantillon

    En service mixte, c’est à dire lors de l’introduction manuelle et par la balance simultanément, les données sont transférées par la balance sur la ligne justement en cours d'édition. Elles doivent être confirmées par <ENTER> sur le Titrino. 795 KFT Titrino...
  • Page 43: Introduire Des Données D'échantillon Dans Le Silo

    Les lignes effacées restent dans la mémoire silo. Leur accès est verrouillé lors du traitement. Pour montrer qu'une ligne a été effacée, elle est marquée par "∗". Les lignes éliminées peuvent être réactivées quand la ligne correspondante est rééditée. 795 KFT Titrino...
  • Page 44 Le mémoire silo comprend 35 lignes. 6 des 35 lignes ont été traitées. Prochaine ligne libre: 36. Les lignes traitées ont été copiées à la fin de la mémoire silo: votre silo est plein jusqu'à la ligne 41. 795 KFT Titrino...
  • Page 45: Mémorisation Des Résultats Et Calculs Silo

    METH> <ENTER>). Le nom du résultat, la valeur et l'unité sont mémorisés. L'encombrement d'une valeur peut être évalué à l'aide des indications suivantes: Résultat avec texte (8 caractères) et unité (5 caractères): 32 bytes Valeur mesurée C40, valeur sans unité: 22 bytes 795 KFT Titrino...
  • Page 46: Calculs Silo

    2.15 Mémorisation des résultats et calculs silo Après le traitement de quelques échantillons, le rapport de la mémoire silo peut se présenter sous la forme suivante (impression avec <PRINT><SILO><ENTER>): 795 KFT Titrino 01103 795.0010 date 2001-11-15 heure 15:03 >silo circ.de données : mémoriser résultats:...
  • Page 47 2.15 Mémorisation des résultats et calculs silo A partir du rapport silo suivant: 795 KFT Titrino 01103 795.0010 date 2001-11-15 heure 15:03 >silo circ.de données: mémoriser résultats: sl méthode id 1/C21 id 2/C22 id 3/C23 11-2 A/12 99-08-12 0.903g 2.6427ml 1.48%...
  • Page 48: Distribution Manuelle

    5. Assignations des moyennes des calculs silo dans C26 et C27 6. Assignations des variables communes 2.16 Distribution manuelle La distribution est exécutée avec la touche <DOS> tant que la touche est pressée. Le débit de distribution est réglé par le potentiomètre analogique du Titrino. 795 KFT Titrino...
  • Page 49: Operation Via Rs232 Interface

    Entries which start with $, trigger some- thing. They are thus called triggers. Values of objects can not only be queried, they can also be modified. Values are always entered in quotes, for example: &Config.Aux.Language "english" 795 KFT Titrino...
  • Page 50: Call Up Of Objects

    'Language' at this level: ..L quire n+1 preceding dots. Change from node 'Language' via the root to If you must jump back to the root, enter a pre- node 'Mode': &M ceding &. 795 KFT Titrino...
  • Page 51: Triggers

    Examples: Querying the value of the baud rate: &Config.RSSet.Baud $Q Querying all values of the node "RSSet": &Config.RSSet $Q Querying the path of the node "RSSet": &Config.RSSet $Q.P Start mode: &Mode $G Querying the detailed status: $D 795 KFT Titrino...
  • Page 52: Status Messages

    $R .Mode.KFT.QuickMeas: Instrument in the KFT mode, inactive. $R .Mode.KFT .Inac: Instrument in the KFT mode, conditioning, endpoint reached. .Cond.Ok: Instrument in the KFT mode, conditioning, endpoint not reached. .Cond.Prog: Buret in the DIS mode, inactive. $R .Assembly.Bur.ModeDis: 795 KFT Titrino...
  • Page 53: Error Messages

    Exit: Send new command. Value has been corrected automatically. Exit: Send new command. Instrument at the end of the titration and sample data is edited; the instrument at rest or editing during filling. Exit: &m $S. 795 KFT Titrino...
  • Page 54 XXX Bytes are missing so that the method or the silo line could not be stored. Exit: Send new command. E155 No new silo result (C24 or C25). Exit: The error message disappears on next start or on recalculation. 795 KFT Titrino...
  • Page 55 Time-out error from PC keyboard (Remote Box) Exit: Rectify error and switch Titrino off and on again. E214 Check Remote Box. Remote Box not (properly) connected but activated in &Config.Periph.RemoteBox. Exit: Rectify error and switch Titrino off and on again. 795 KFT Titrino...
  • Page 56: Remote Control Commands

    Administration of the internal user-memory for methods ├ Config Instrument configuration ├ SmplData Sample specific data ├ Hotkey Keys with direct access ├ Info Current Data ├ Assembly Component data ├ Setup Setting the operating mode └ Diagnosis Diagnostics program 795 KFT Titrino...
  • Page 57 Input of variable RSX, EPX, CXX 3.2.2.9. │ │ │ │ ├ .TempVar without meaning ├ .CFmla Calculation constants │ ├ Calculation constant C01 │ │ ├ .Value Input of value 0...±999999 3.2.2.10. │ ├ up to C19 795 KFT Titrino...
  • Page 58 .LoLim Lower limit 0.0...999 999 ditto │ │ ├ .UpLim Upper limit 0.0...999 999 ditto │ ├ .Oven KF Oven connected COM1, COM2, no 3.2.2.28. │ ├ .ActPulse Output of a pulse first, all, cond., OFF 3.2.2.29. 795 KFT Titrino...
  • Page 59 │ │ ├ .DosUnit Dosing element read only ditto │ │ ├ .Bytes Method size in bytes read only ditto │ │ ├ .Checksum Checksum of method read only ditto ├ for each method 795 KFT Titrino...
  • Page 60 Time counter 0...9999 ditto │ │ ├ .ClearCount Clears the counter above ditto │ ├ .Service Monitoring of Metrohm service 3.2.2.34. │ │ ├ .Status Status of service monitoring ON, OFF ditto │ │ ├ .Date Date of next service...
  • Page 61 │ ├ .Handsh Handshake HWs, SWchar, │ │ SWline, none ditto ├ .RSSet2 as for RS1 │ ├ .ComVar Values of common variables │ ├ .C30 0... ±999999 3.2.2.50. │ ├ up to C39 0... ±999999 795 KFT Titrino...
  • Page 62 .DelLine Delete silo line 3.2.2.55. │ │ ├ .LineNum Line number 1...255, OFF ditto │ ├ .DelAll Delete silo line 3.2.2.56. │ ├ .CycleLines Cycle lines ON, OFF 3.2.2.57. │ ├ .SaveLines Save results ON, OFF 3.2.2.58. 795 KFT Titrino...
  • Page 63 10 ASCII char ditto │ ├ .DelAll Delete all users ditto │ ├ .List List of users │ │ ├ User 1 │ │ │ ├ .Name Name of user read only ditto │ │ ├ up to 99 795 KFT Titrino...
  • Page 64 │ │ ├ .C43 Volume drift read only/read+write │ │ ├ .C44 Titration temperature read only/read+write │ │ ├ .C45 Start volume read only/read+write │ │ ├ .DTime Time for drift corr.or dosing time read only/read+write 795 KFT Titrino...
  • Page 65 │ │ ├ Z2 coordinate read only ditto │ ├ EP entry │ │ ├ .Index Index of entry read only ditto │ │ ├ X coordinate read only ditto │ │ ├ Y coordinate read only ditto 795 KFT Titrino...
  • Page 66 │ ├ .Comport Comport │ │ ├ .Number COM where PC is connected read only 3.2.2.74. │ ├ .Assembly Assembly │ ├ CycleTime Cycle time read only 3.2.2.75. │ ├ Volume of Exchange/Dosing unit read only ditto 795 KFT Titrino...
  • Page 67 3.2.2.80. │ ├ .SetLines Set I/O lines ditto │ │ ├ Signal on L0 active,inactive,pulse,OFF ditto │ │ ├ up to L13 │ ├ .ResetLines Reset I/O lines ditto │ ├ .Stirrer Stirrer ON, OFF 3.2.2.81. │ 795 KFT Titrino...
  • Page 68 Measured indicator voltage ON, OFF ditto │ │ ├ .dVdt Volume drift dV/dt ON, OFF ditto │ │ ├ .dMeasdt Measured value drift ON, OFF ditto │ │ ├ .dMeasdV 1st deviation of titration curve ON, OFF ditto │ 795 KFT Titrino...
  • Page 69 .Initialise Set default values 3.2.2.95. │ ├ .Select Selection of branch ActMeth,Config,Silo, │ Assembly,Setup,All ditto ├ .RamInit Initialization of working mem. 3.2.2.96. ├ .InstrNo Device Identification 3.2.2.97. ├ .Value Input of device identification 8 ASCII characters ditto 795 KFT Titrino...
  • Page 70 3.2 Remote control commands &Diagnose Object Description Input range Reference & Root ├ Diagnose Diagnose ├ .Report Output of adjustment parameters 3.2.2.98. 795 KFT Titrino...
  • Page 71: Description Of The Remote Control Commands

    In place of "RSX", a result name may be entered (.TextRS). This name is out- putted in the report full, short, scalc full and scalc srt. It is used for the result and the corresponding mean value. 795 KFT Titrino...
  • Page 72 Calculation constants specific to a method. Stored in the method memory of the Titrino. Operands specific to the sample (3.2.2.52 and 3.2.2.63) and val- ues of common variables (3.2.2.50) on the other hand are not stored with the methods. 795 KFT Titrino...
  • Page 73 .Time is set to "inf.". 3.2.2.14. Mode.Parameter.TitrPara.Direction +, –, auto Titration direction. "auto" means the titration direction is determined automatically by the instru- ment. 3.2.2.15. Mode.Parameter.TitrPara.XPause 0...999999 Pause time in s. Runs before dosing the start volume. 795 KFT Titrino...
  • Page 74 (titration or conditioning). 3.2.2.20. Mode.Parameter.TitrPara.Temp –170.0...25.0...500.0 Titration temperature in °C. 3.2.2.21. Mode.Parameter.TitrPara.TDelta 1...2...999999 Time interval in s for the entry of a measurement point in the list of measured points. 795 KFT Titrino...
  • Page 75 OFF Mode.Parameter.Presel.DCor.Value 0.0...99.9 .Cond: Conditioning ON/OFF .DriftDisp: Drift display during conditioning ON/OFF. .DCor.Type: Type of drift take-over for the drift correction. auto: Take-over of the drift value at start. .DCor.Value: Drift value for the manual drift correction. 795 KFT Titrino...
  • Page 76 Management of the internal method memory: Load, store and delete methods. An action is performed if "$G" is sent to the corresponding node just after en- tering the name. Do not use blank characters before and after method name! .DelAll: Deletes all methods in the user memory. 795 KFT Titrino...
  • Page 77 Select 'IBM' for work with the computer. 3.2.2.37. Config.PeriphUnit.RepToComport 1, 2, 1&2 Selection of COM of the Titrino where manually triggered reports should be outputted. 3.2.2.38. Config.PeriphUnit.Balance Sartorius,Mettler,Mettler AT, AND,Precisa Selection of the balance type. 795 KFT Titrino...
  • Page 78 Number of automatic, internal starts. 3.2.2.45. Config.Aux.StartDelay 0...999999 Start delay time in s. During this time, the data of the preceding determination are retained. 3.2.2.46. Config.Aux.ResDisplay bold, standard Character set for the result display at the end of the determination. 795 KFT Titrino...
  • Page 79 3.2.2.7. 3.2.2.51. SmplData.Status ON, OFF On/off switching of silo memory. When the silo memory is switched on, the sample data are fetched from the lowest valid silo line. 795 KFT Titrino...
  • Page 80 Silo lines which have been worked off are "read only". 3.2.2.55. SmplData.ONSilo.DelLine SmplData.ONSilo.DelLine.LineNum 1...255, OFF Deletion of a silo line. The line # is deleted with &SmplData.ONSilo.DelLine $G. If a formerly deleted line is edited again, it becomes valid (function "unde- lete"). 795 KFT Titrino...
  • Page 81 Curve volume vs. time of the last determination. scalc full: Full report of the silo calculations. scalc srt: Short report of the silo calculations. calc: Calculation report of the current method. all: All reports. Form feed on printer. 795 KFT Titrino...
  • Page 82 &Info.DetermData.MP.List, &Info.TitrResults.Var.C4X (X = 0...5), and &Mode.Name. .ExV: Volume of the exchange unit, with which the determination was executed .MPList.1.Attribute: Attribute .MPList.X: X coordinate, time .MPList.Y: Y coordinate, volume .MPList.Z1: Z1 coordinate, measuring value .MPList.Z2: without meaning 795 KFT Titrino...
  • Page 83 Info.SiloCalc.C26.Mean read only Info.SiloCalc.C26.Std read only Info.SiloCalc.C26.RelStd read only for .C27 as for .C26 The current values from the silo calculations. C26 is the mean value out of the C24 variables; C27 comes from C25. 795 KFT Titrino...
  • Page 84 "127". From the cycle number and the cycle time (see 3.2.2.75), a time frame can be set up. The cycle number is set to 0 on switching on the instrument, on every start and for QuickMeas. It is incremented as long as the instrument remains switched on. 795 KFT Titrino...
  • Page 85 Info.ActualInfo.MeasPt.Z1 read only Info.ActualInfo.MeasPt.Z2 read only Info.ActualInfo.EP.Index read only Info.ActualInfo.EP.X read only Info.ActualInfo.EP.Y read only $Q sends the last entry into the measuring point list (.MeasPt) or the last entry into the list of EP's. 795 KFT Titrino...
  • Page 86 $Q sends the comport number of the Titrino where the PC is connected. 3.2.2.75. Info.Assembly.CycleTime read only Info.Assembly.ExV read only Inquiries regarding basic variables of the assembly: Cycle time in s, volume of the active Exchange Unit in mL. 795 KFT Titrino...
  • Page 87 Control. When the measuring function is switched on, no method can be started at the Titrino. .Input: Selection of the "measuring input" for polarized electrodes. .Ipol: Polarization current in µA. .Upol: Polarization potential in mV, entry in steps of 10 mV. 795 KFT Titrino...
  • Page 88 L8–13 .ResetLines: Lines are set to the inactive status (= high). 3.2.2.81. Assembly.Stirrer ON, OFF Switching stirrer ON/OFF. 3.2.2.82. Setup.Comport 1, 2, 1&2 Selects the Titrino COM for the output of automatic info: &Setup.Keycode &Setup.Trace &Setup.SendMeas &Setup.AutoInfo 795 KFT Titrino...
  • Page 89 .UserMeth.Store: Disable "store" in <user meth> key .UserMeth.Delete: Disable "delete" in <user meth> key .Display: Disable the display, i.e. it will not be written to by the device pro- gram of the Titrino and can be operated from the computer. 795 KFT Titrino...
  • Page 90 ON, OFF Setup.SendMeas.Titrator.V ON, OFF Setup.SendMeas.Titrator.Meas ON, OFF Setup.SendMeas.Titrator.dVdt ON, OFF Setup.SendMeas.Titrator.dMeasdt ON, OFF Setup.SendMeas.Titrator.dMeasdV ON, OFF Selection of the values from the titrator which are sent in the set time interval (see 3.2.2.88, formats see 3.2.2.70): 795 KFT Titrino...
  • Page 91 Continue: Continue after hold. .T.O Conditioning OK: EP reached (in KFT with conditioning). .T.N Conditioning Not OK: EP not reached (in KFT with conditioning). .T.Re Request: In the inquiry of an identification or the sample size after start of titration. 795 KFT Titrino...
  • Page 92 1 means the measured value axis is plotted over the entire width of the paper (largest possible width). In extreme cases, the writing of the right tick may lie outside. 795 KFT Titrino...
  • Page 93 Initializes instrument, see page 110. All parameters are set to their default value and error messages are cleared. The user and silo memories will be de- leted. The user memory contains the default user methods from Metrohm. 3.2.2.97. Setup.InstrNo Setup.InstrNo.Value serial number, 8 ASCII characters Instrument identification for report output.
  • Page 94: Properties Of The Rs 232 Interface

    Parity Bit 1 or 2 Stop Bit Only a shielded data cable (for example, METROHM D.104.0201) may be used to couple the Titrino with foreign devices. The cable shield must be properly grounded on both instruments (pay attention to current loops; always ground in a star-head formation).
  • Page 95 Handshake output ports (DTR, RTS) are set by the Titrino. The Titrino has an input buffer which can accept up to 512 characters. Titrino as Receiver : Titrino external device max. 128 characters Data output 384 characters XOFF Data input Time 795 KFT Titrino...
  • Page 96 6 s by XOFF, E43 appears in the display. Hardware-Handshake, HWs Titrino as Receiver : Titrino external device Time Titrino as Sender: Titrino external device Time The data flow can be interrupted by deactivating the CTS line. 795 KFT Titrino...
  • Page 97: Pin Assignment

    (<–3 V): OFF state voltage positive (>+3 V): ON state In the transitional range from +3 V to –3 V the signal state is undefined. Driver 14C88 according to EIA RS 232C specification Receiver 14C89 " " 795 KFT Titrino...
  • Page 98 Contact arrangement at plug (female) for RS 232C socket (male) View of soldered side of plug Ordering numbers: K.210.0381 and K.210.9045 No liability whatsoever will be accepted for damage or injury caused by im- proper interconnection of instruments. 795 KFT Titrino...
  • Page 99: Que Faire, Si La Transmission Des Données Ne Fonctionne Pas

    • Est-ce que vous utilisez un câble correct? (DTR de l'imprimante doit être connecté avec CTS du Titrino .) • Ajuster le handshake du Titrino à "HWs". Ajuster l'imprimante de façon que son DTR soit mis (éventuellement avec switch DIP). 795 KFT Titrino...
  • Page 101: Messages D'erreur, Dérangements

    - Le lecteur de codes bandes livre des signaux endommagés - La Remote-box est défectueuse Solution: corriger l’erreur et mettre le Titrino hors/sous tension. Parité. Erreur de réception. error 36 Sortie: <QUIT> et ajuster la même valeur sur les deux appareils. 795 KFT Titrino...
  • Page 102 Sortie: émettre L ou <QUIT>. L’intervalle de service est écoulé. Appeler le département de exécuter service service Metrohm, afin de réaliser l’entretien du Titrino. Le message d’erreur apparaît à chaque mise sous tension du Titrino. Sortie: nouveau départ. Un EP utilisé dans une formule manque pour le calcul.
  • Page 103 - Problème à la Remote-box Solution: mettre sous <CONFIG>, >Appareils périphériques "remote-box:non", éteindre le Titrino, enlever la Remote-box et allumer de nouveau le Titrino. Appeler le Service Metrohm. Une adresse a été appelée du clavier ordinateur connecté (par time out clavier PC exemple <F12>), puis la liaison a été...
  • Page 104: Diagnostic

    4.2 Diagnostic 4.2 Diagnostic 4.2.1 Généralités Le 795 KFT Titrino est un appareil très précis et fiable. Grâce à sa construction robuste, ses fonctions ne peuvent guère être gênées par des influences extérieures mécanique sou électriques. Bien que des dérangements ne soient pas complètement exclus, des pannes dues à de fausses manœuvres ou de fausses connexions avec des appareils étrangers semblent...
  • Page 105: Appareillage Nécessaire

    • Le déroulement du test peut être arrêté ou remis en marche par la touche <5>. • On quitte le bloc 2 par la touche <CLEAR>. d i a g n o s e p r e s s k e y 0 . . . 9 795 KFT Titrino...
  • Page 106: Test Du Clavier

    Clavier 795 • On quitte le bloc 1 en appuyant deux fois sur la touche <CLEAR>. d i a g n o s e p r e s s k e y 0 . . . 9 795 KFT Titrino...
  • Page 107: Code Cylindrique, Date, Heure

    - t i m e r t e s t o . k . • Appuyer sur <CLEAR>. d i a g n o s e p r e s s k e y 0 . . . 9 795 KFT Titrino...
  • Page 108: Test De L'entrée De Mesure

    . k . • Appuyer sur <CLEAR>. d i a g n o s e p r e s s k e y 0 . . . 9 • Débrancher le 767 ou les câbles et décade de résistance. 795 KFT Titrino...
  • Page 109: Entrées Et Sorties Externes

    Entrées et sorties externes Ce test n'a de sens que si le 795 KFT Titrino est utilisé avec d'autres appareils via la fiche à la connexion ‘Remote‘ ou lorsque la Remote-box 6.2148.000 est utilisée pour la connexion d’un clavier PC ou d’un lecteur codes bandes. Si la Remote-box doit être testée, il faut alors connecter cette dernière au Titrino avant la mise au secteur.
  • Page 110 Par souci d’intégrité, le procédé est décrit ci-dessous. Si le diagnostic de l’interface RS232 n’est pas nécessaire, continuer sous point 9. Fig. 5 Connexions à la fiche 3.496.8560 • Appuyer sur <5>. RS232 test 1...2 795 KFT Titrino...
  • Page 111 • Retirer la fiche test. • Appuyer sur <CLEAR>. RS232 test 1...2 • Appuyer sur <CLEAR>. d i a g n o s e p r e s s k e y 0 . . . 9 795 KFT Titrino...
  • Page 112: Distributeur Interne D

    Règle générale: La tige hélicoïdale et le robinet doivent se mouvoir à une allure constante (bruit!). En position 'remplir' l'accouplement du robinet doit pousser le levier de l'unité Inter- changeable complètement contre la butée gauche (sans jeu et sans coincer). • Amener le potentiomètre 'dV/dt' à la butée gauche. 795 KFT Titrino...
  • Page 113: Remise À L'état Initial

    • Amener le potentiomètre 'dV/dt' à la butée droite. • Appuyer sur <FILL>. 10 Remise à l'état initial Rétablir les connexions avec les appareils périphériques interrompues en début de diagnostic, puis les soumettre à un bref test de fonctionnement. 795 KFT Titrino...
  • Page 114: Initialisation Du Ram

    <CLEAR>. Toutes les données de base de mise au point se trouvent automatiquement chargées. Ainsi, l'appareil demeure en état de mesurer. Il faut ce- pendant compter avec une certaine perte de précision. Le Service Metrohm pourra procéder à une mise au point optimale. Jusqu'à ce que celle-ci ait lieu, l'indication apparaîtra toujours après la mise sous tension de l'appareil.
  • Page 115: Dépannage D'une Tige Hélicoïdale Bloquée Avec L'unité Interchangeable Installée

    Les cablages électroniques sont maintenant à nu! Ne les toucher en aucun cas! • Dégager la tige hélicoïdale en tournant la grande roue dentée. (Si le moteur est inactif, abaisser la tige à la position 0 à la main.) 795 KFT Titrino...
  • Page 116: Préparatifs

    5.1.1 Titrino avec agitateur magnétique ou Poste Ti Câble de l'agitateur Agitateur ou Poste Ti Clavier 6.2130.070 Au lieu de l'agitateur magnétique 728, on peut également brancher l'agitateur à tige 802 ou le Poste Ti 727 ou 703 avec le câble 6.2108.100. 795 KFT Titrino...
  • Page 117: Branchement D'une Imprimante

    9600 DPU-414 Data bit: Stop bit: Aucun Parité: Handshake: Transm.à: Seiko Custom 6.2134.110 Baud rate: 9600 Pas nécessaire, la version Metrohm DP40-S4N Data bit: est configurée correctement Stop bit: IDP-560 EMULATION FONT MAP =GERMANY Parité: PRINT=REVERSE Handshake: LITTLE CR CODE=VOID Transm.à:...
  • Page 118: Branchement D'une Balance

    émis par la balance ne sont pas transmis. Une unité d'introduction spéciale livrée par le fabricant de balance permet d'introduire par la balance, en plus de la prise d'essai, les identifications de l'échantillon et la méthode. Les adresses des iden- 795 KFT Titrino...
  • Page 119: Branchement D'un Four Kf

    6.2041.180 La connexion des deux interfaces RS (câble 6.2125.110) est seule- ment nécessaire, lorsque les résultats du Four doivent être intégrés dans le rapport du Titrino 795. Du Four, il ne doit s’ensuivre aucune sortie de rapport! 795 KFT Titrino...
  • Page 120: Branchement D'un Passeur D'échantillons

    Câble 6.2141.020 Avec le câble 6.2141.030 (à la place de 6.2141.020) on peut connec- ter deux Titrinos au passeur d'échantillons 730 (ou 760). • La prise "Remote", outre le branchement d'un passeur d'échantillons, permet d'exécuter d'autres fonctions de 795 KFT Titrino...
  • Page 121: Branchement De L'oven Sample Processor 774

    En plus, il est possible via une liaison RS, pendant le déroulement d’une séquence à partir de l’Oven Sample Processor de charger dans le Titrino une méthode définie. Par l’intermédiaire de la liaison RS, il est également possible d’interroger les paramètres du Four à partir du Titrino. 795 KFT Titrino...
  • Page 122: Branchement D'un Ordinateur

    Si on veut brancher simultanément un lecteur de codes bandes et un clavier d’ordinateur, il faut que le premier ait une prise de dérivation en forme de T. Le clavier ordinateur peut alors être branché sur cette connexion du lecteur de codes ban- des. 795 KFT Titrino...
  • Page 123: Réglages Au Titrino

    Si votre clavier n’est pas accepté par le Titrino, choisir le clavier le plus près possible du votre (contrôler avec les fonctions secondaires des touches numériques par exemple). Les signes particuliers spécifiques du pays ne seront cependant probablement pas tra- duits correctement. 795 KFT Titrino...
  • Page 124: Commande Via Clavier Ordinateur

    R1 donne RS1. <ENTER> enter <MEAS/HOLD> <MODE> <PARAM> <PRINT> Alt P Choix du rapport avec → ← <QUIT> <REPORTS> Alt O Impression rapports: Alt P+Alt O <SILO> Oui/non <SMPL DATA> <START> <STATISTICS> Oui/non <STOP> <USER METH> <USER> Alt U 795 KFT Titrino...
  • Page 125 (Overlay). Vous pouvez copier cette représentation, découper la partie du milieu et la placer sur les touches de fonction de votre clavier ordinateur. Silo Clear Statistics Start Stop Meas/Hold Config Param SmplData 795 KFT Titrino...
  • Page 126: Branchement De L'électrode, Installation Du Vase De Titrage

    Raccord à vis 6.2730.030 6.2730.010 Bouchon septum 18 m m 6.2730.020 Septum 6.1448.010 Set de joints 6.1244.040 Partie supérieure du vase de titrage 6.1414.030 Partie inférieure du vase de titrage 20...90 m L 6.1415.220 Barreau d'agitation m agnétique 6.1903.020 795 KFT Titrino...
  • Page 127: Annexe

    Gamme 100 x 37 mm Illuminé par LED Mémoire interne Mémoire de méthodes pour environ 100 méthodes Banque de données avec 18 méthodes Metrohm Mémoire silo pour données d’échantillons et résultats Interfaces RS232 2 interfaces configurables séparément pour imprimante, balance ou ordinateur: commande com- plète à...
  • Page 128: Spécifications De Sécurité

    Tension 100...240 V Fréquence 50...60 Hz Puissance absorbée 15 W Fusible 2 x 1 ATH (à remplacer par le Service Metrohm par le même type) Protection de surcharge électronique additionnelle Dimensions avec unité Interchangeable Largeur 150 mm Hauteur 450 mm...
  • Page 129: Attribution Des Contacts De La Prise "Remote

    +5 V libre pin 24 (Entrée 6) +5 V pin 12 (Entrée 7) Sorties pin 5 (Sortie 0) Ready inactive pin 18 (Sortie 1) Conditioning OK, actif si Cond.ok pin 4 (Sortie 2) Titrage, actif pendant le titrage 795 KFT Titrino...
  • Page 130 I ≤ 200 mA +5 V pin 14 0 V: actif 5 V: inactif pin 25 Numéro de commande pour fiche: K.210.9004 (douille) et K.210.002 Nous refusons toute responsabilité quant aux dommages occasion- nés par une interconnexion inappropriée des appareils. 795 KFT Titrino...
  • Page 131 6.2 Attribution des contacts de la prise "Remote" 6.2.1 Etat des lignes de la prise "Remote" 795 KFT Titrino...
  • Page 132: Impulsion "Activation" En Mode Kft

    6.2 Attribution des contacts de la prise "Remote" 6.2.2 Impulsion "activation" en mode KFT cond. tout prem. Etat inactif START Conditionnement START Demande id... Start titrage end of det. (EOD) Sortie données 795 KFT Titrino...
  • Page 133: Méthodes D'utilisateur

    éliminer les rapports sous la touche <DEF>, >Rapport. Si vous avez besoin d’une autre unité pour le résultat, il vous faudra éventuellement ajus- ter les valeurs de calcul sous la touche <C-FMLA>. Les méthodes suivantes sont disponibles: 795 KFT Titrino 01103 795.0010 utilisateur...
  • Page 134 Karl-Fischer-Titration according to demande p.d'essai: Eugen Scholz, Riedel de Haën, Seelze, limites p.d’ess: four: Germany activation impuls: METROHM Application Bulletin Nr. 77: ------------ Dosage de l’eau par la méthode Karl Fischer 795 KFT Titrino 795.0010 date 2001-11-15 heure 17:58...
  • Page 135: Titre Kf Avec Tartrate De Sodium "Tartiter

    Karl-Fischer-Titration according to demande ident: Eugen Scholz, Riedel de Haën, Seelze, demande p.d'essai: limites p.d’ess: Germany four: METROHM Application Bulletin Nr. 77: activation impuls: Dosage de l’eau par la méthode Karl Fischer ------------ 795 KFT Titrino 795.0010 date...
  • Page 136: Détermination De La Valeur À Blanc Pour Kft "Blank_Kf

    HYDRANAL® Practical Course, Water re- activation impuls: agents for Karl-Fischer-Titration according to ------------ Eugen Scholz, Riedel de Haën, Seelze, Germany METROHM Application Bulletin Nr. 77: 795 KFT Titrino 795.0010 Dosage de l’eau par la méthode Karl Fischer date 2001-11-15 heure 18:01...
  • Page 137: Titrage Kf Avec Déduction De La Valeur À Blanc "Kf-Blank

    Karl-Fischer-Titration according to demande p.d'essai: tous Eugen Scholz, Riedel de Haën, Seelze, limites p.d’ess: Germany four: METROHM Application Bulletin Nr. 77: activation impuls: Dosage de l’eau par la méthode Karl Fischer ------------ 795 KFT Titrino 795.0010 date 2001-11-15...
  • Page 138 6.3 Méthodes d’utilisateur 795 KFT Titrino 795.0010 date 2001-11-15 heure 18:04 Ipol KF-Blank >Formule Water=(EP1-C38)*C39*C01/C00/C02 RS1 texte Water RS1 nombre décimales RS1 unité: RS1 contrôle limites: Titer=C39 RS2 texte Titer RS2 nombre décimales RS2 unité: mg/ml RS2 contrôle limites: Blank=C38...
  • Page 139: Titrage Kf Sans Déduction De La Valeur À Blanc "Kf

    >Présélections agents for Karl-Fischer-Titration according to conditionner: Eugen Scholz, Riedel de Haën, Seelze, indic.dérive: Germany corr.dérive: METROHM Application Bulletin Nr. 77: demande ident: Dosage de l’eau par la méthode Karl Fischer demande p.d'essai: tous limites p.d’ess: four: activation impuls:...
  • Page 140 6.3 Méthodes d’utilisateur 795 KFT Titrino 795.0010 date 2001-11-15 heure 18:06 Ipol > Formule Water=EP1*C39*C01/C00/C02 RS1 texte Water RS1 nombre décimales RS1 unité: RS1 contrôle limites: Titer=C39 RS2 texte Titer RS2 nombre décimales RS2 unité: mg/ml RS2 contrôle limites: >Calcul silo comparer …...
  • Page 141: Titrages Kf Avec Différents Réactifs Kf

    Si vous utilisez différents milieux de titrage parallèlement, prenez garde à bien attribuer les valeurs des titres des différents titrants à des variables communes différentes; chacune d’entre elles étant ensuite utilisée dans sa méthode de titrage propre. 795 KFT Titrino...
  • Page 142: Détermination De L'indice De Brome "Brnumber

    100...200 1.0...0.5 RS1 texte BrNumber RS1 nombre décimales Bibliographie: RS1 unité: ASTM D 1159-84 RS1 contrôle limites: >Calcul silo Metrohm Application Bulletin Nr. 177 comparer … id: >Variables communes >Rapport Rapport COM1:compl; >Moyenne MN1=RS1 >Variables temporaires ------------ 795 KFT Titrino...
  • Page 143: Validation Du Titrino

    Le bulletin d’application Metrohm suivant donne des informations utiles sur les méthodes de contrôle (SOP, Standard Operating Procedure): N°. 255: Validation des titreurs KF Metrohm et Fours KF selon GLP/ISO 9001. L’intervalle de validation peut être contrôlé par le Titrino (réglage sous <CONFIG>, Contrôle).
  • Page 144: Garantie Et Conformité

    6.5 Garantie et conformité 6.5.1 Garantie Les produits Metrohm jouissent d'une garantie de 12 mois à partir de la date de livraison. Est garantie, la remise en état gratuite, dans nos ateliers, de tous défauts imputables avec certitude à des défauts de matériau, de construction ou de fabrication.
  • Page 145: Attestation De Conformité Ue

    6.5 Garantie et conformité 6.5.2 Attestation de conformité UE Attestation de conformité UE La société METROHM SA, Herisau, Suisse, atteste par la présente que l'appa- reil: 795 KFT Titrino répond aux spécifications des directives 89/336/CEE et 73/23/CEE de l'UE. Sources des spécifications: EN 50081 Compatibilité...
  • Page 146: Certificat De Conformité Et De Validation Du Systéme

    The features of the system software are documented in the instruc- tion manual. Metrohm Ltd. is holder of the SQS-certificate of the quality system ISO 9001 for quality assurance in design/development, production, installation and servicing. Herisau, October 30, 2001 Dr.
  • Page 147: Programme De Livraison Et Numéros De Commande

    1 Vesuv 3.0 light, logiciel pour l'acquisition des données et le backup des méthodes pour 2 appareils .................... 6.6008.500 1 Mode d'emploi pour Titrino KFT 795 ..............8.795.1002 1 Aperçu rapide pour Titrino KFT 795 ..............8.795.1012 1 Mode d'emploi abrégé pour Titrino KFT 795............. 8.795.1022 795 KFT Titrino...
  • Page 148 Accessoires livrables sur commande et contre facturation séparée: Burettes Burettes auxiliaires Dosimat 765 ......................2.765.0010 Dosimat 776 ......................2.776.0010 Câble 795 KFT Titrino (pulsation d’activation) - 765 ou 776 Dosimat....6.2139.000 Unités interchangeables V = 1 mL ......................6.3026.110 V = 5 mL ......................
  • Page 149 Câble Titrino KFT 795 — PC (9/25 pôles) ............6.2125.110 Câble d'allongement RS232 C (25/25 pôles) ............6.2125.020 Câble d'allongement RS232 C (9/9 pôles) ............6.2134.110 Vesuv 3.0, logiciel pour l'acquisition des données et le backup des méthodes pour jusqu'à 64 appareils ................6.6008.200 795 KFT Titrino...
  • Page 150: Passeur D'échantillons

    Câble Titrino — P. d'échantillons 730, 760+Dosimat 665, 725, 765, 776 ... 6.2141.040 Câble Titrino — P. d'échantillons 730, 760+2x Dosimat 665, 725, 765, 776 ..6.2141.050 Câble Titrino KFT 795 — 664 Contrôleur pour p. d'échantillons 673/674.... 3.980.3560 795 KFT Titrino...
  • Page 151: Index

    Curseur............6 <CURVE> ..........33 Câbles ..........145ss .........41, 42 Calcul silo ..........12 data bit: Calculs statistiques ........28 ............11 date Calculs............25 ..........18 débit rempl. CE ............141 Débit de remplissage Certificats..........141 après les distributions manuelles..4 795 KFT Titrino...
  • Page 152 Erreur, messages......49ss, 97ss ......11 Lecteur codes bandes ..........97-98 error XX Lecteur codes bandes......118 ............28 état: LED's ............. 3, 29 Etats détaillés ..........48 ........... 39 ligne du silo ........98 exécuter service Lignes I/O..........125 795 KFT Titrino...
  • Page 153 ........99 résultat hors lim. Paramètres de titrage KFT ......15 ........ 26 RS1 contrôle limite ............12 parité: ......... 26 RS1 Ligne L13: ...........98 pas de......... 26 RS1 limite inf..........99 pas possible ........26 RS1 limite sup. 795 KFT Titrino...
  • Page 154 PC Titrage Karl Fischer ....... 15ss Volume de départ ........17 Touche <ABC>..........8 <C-FMLA> ......... 27 <CLEAR> ..........6 <CONFIG>........... 9 <CURVE>........... 33 <DEF>..........25ss <DOS> ..........3 <ENTER> ..........6 <MEAS/HOLD>........6 <MODE> ..........14 795 KFT Titrino...

Table des Matières