4. GENERAL SPECIFICATIONS
4.1 Dimensions and weight
70 x 193 x 37 mm
I
I
4.2 Clamp Tightening Capacity
≤ 26 mm
I
4.3 Power supply
A standard 9 V alkaline battery (type IEC 6LF22, 6LR61
I
or NEDA 1604). To change it, see §7.1.
Average battery charge life: 75 h or 25.000 x 10 s.
I
measurement
Battery charge indicator
I
Flashing: charge life < 1 h
Fixed: Change battery
Automatic OFF after 10 minutes with no action on the switch
I
or the keys (reactivation by switching from the OFF position
of the switch or by actuating any key)
4.4 Environmental parameters
Temperature - Humidity
I I I I I
90
80
70
60
50
40
30
20
10
0
-50
-40
-30
-20
-10
0
10
Temperature in °C
Reference range
Storage range (without battery)
Altitude
I I I I I
- Operation: ≤ 2000 m
- Storage ≤ 12000 m
Indoor use
I I I I I
Impermeability: protection index IP 40 (according to EN
60529)
4.5 Compliance with norms
Electrical safety
I I I I I
(as per EN 61010-1 and 61010-2-032)
-
Dual insulation:
-
Installation category: III
-
Pollution level: 2
-
Rated voltage: 600 V (RMS or DC)
or -
Installation category : IV
-
Rated voltage : 300V (RMS or DC)
260 g
:
+
-
20
30
40
50
60
70
80
90
Operating range
42