1. After the power is on (or press MODE/POWER for 3 seconds) the displays shows all functions for 1
second, then enters SCAN mode.
2. As soon as pedal strokes (COUNT) are measured, each function starts counting (TIME, CALORIES,
REPS/MIN).
3. When no more pedal strokes (COUNT) are measured, each function stops counting, the console
pauses and displays STOP.
E. Mode Button Function Description
1. Switch between different modes pressing the button repeatedly. During SCAN mode, the screen will
stay on the current function.
2. If you press the button for 3 seconds you will return to 0 (Reboot to clear all other data than COUNT).
3. APP connection via Bluetooth.
Slot for battery
replacement
1. Carefully pull the display out of the main unit. The battery compartment is on the back of the com-
puter.
2. Insert the tip of a thin flat-blade screwdriver into the slot. Now carefully push the screwdriver to the
side so that the battery pops out due to the leverage.
3. Remove the battery and replace it with a new 3V CR2032 battery.
4. Pay attention to the correct polarity placement when inserting the battery!
5. Press the "MODE" button to check the function. Make sure that the battery is charged and replace
or reinstall the battery if necessary.
6. Carefully put the display back into the main unit returning it to its original position.