Installation; General - Hatco IWB Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

General

Built-In Ice Wells are shipped from the factory as components
that require installation and connection. Use the following
procedures to install each component and make the
appropriate connections.
WARNING
This unit must be installed by qualified, trained installers.
Installation must conform to all local plumbing codes.
Check with local plumbing inspectors for proper
procedures and codes.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
NOTICE
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to unit.
all Built-In Ice Wells are shipped in a wooden frame for
protection and stability. Keep the unit in the wooden frame until
the unit and the installation site are completely prepared for the
unit to be installed.
1. Remove all external packaging from the unit.
2. Remove tape, protective packaging, and literature from all
surfaces of unit.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION section for
details.
3. Cut the appropriate opening in the countertop for the unit
being installed. Refer to "Countertop Cutout Dimensions"
in this section.
4. make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents.
NOTE: The countertop must be level to ensure proper draining
of the well.
Form No. IWBm-0816
5. Carefully lower unit into the countertop cutout. This step
requires two or more people, depending on the unit.
Installing an Ice Well
6. apply National Sanitation Foundation-approved (NSF-
approved) silicone sealant around the edge of the unit to
seal it to the countertop.
7. Connect the 1" drain fitting to a trap and drain line. If a trap
and drain line are not available, a catch pan (not supplied)
must be used under the drain fitting to contain water
draining from the well enclosure.
NOTE: Consult a qualified plumber for proper trap and drain
installation that conforms to local plumbing codes.
8. Clean the well enclosure thoroughly in preparation for initial
operation. Refer to the maINTENaNCE section for proper
cleaning procedures.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the pan is emptied regularly to prevent over-flowing.
5

INSTALLATION

Ice
Well
Countertop
Cutout

Publicité

Table des Matières
loading

Table des Matières