• I f the environment in which the product is installed also houses a fuel-operating device
(water heater, methane stove etc., that is not a "sealed chamber" type), it is essential
to ensure adequate air intake, to ensure good combustion and proper equipment
operation.
• I nstall the product so that the impeller is not accessible from the air outlet side as
verified by contact with the Test Finger (test probe "B" of the norm EN61032) in
compliance with the current safety regulations.
• C eiling installation
In order to guarantee the IPX4 degree of protection against moisture in case of ceiling
installation, use the appropriate ceiling mount kit, which is not included. Use only the
rear entry hole for supply cables. If there is a possibility of condensation along the air
discharge duct, provide a drainage system to prevent condensation from discharging
into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
• W indow installation
In case of window installation it is necessary to use the appropriate window kit, which
is not included.
Attention: do not mount the product on the window without this kit.
INTRODUCTION
Quantum AX (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air
extraction in small/medium-sized rooms.
Suitable for air discharge directly to the outside or in the presence of short ducted system.
Wall, ceiling or window installation (fig. 2).
TECHNICAL SPECIFICATIONS
• M aterial: High quality, impact and UV-resistant ABS colour RAL 9010.
• D esign front cover removable for cleaning without the use of tools.
• R ear reinforcement ring to prevent spigot deformation during installation.
• H igh efficiency aerodynamic fan with "winglet" blades to optimise quietness and
efficiency.
• S ingle phase EC Brushless motor with integral thermal protection.
• M otor mounted on high quality ball bearings.
• T he fan is double insulated: no earth connection is required.
• T rickle speed selectable during installation: 6, 8, 13 l/s or off.
• O ption to boost from trickle (or from off) through LS connection or pull cord (only pull
cord versions).
• I nstallation type selection available (through wall or ducted).
• T imer and Integral Humidistat versions available.
• I PX4 degree of protection.
• P ower supply 220V to 240V~ 50/60Hz.
Model
Quantum AX
VERSIONS
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch combination
fig. 16) and can be boosted with a dedicated ON/OFF switch (or PIR, CO2... sensor) or
with a light switch (fig. 14A). Trickle speed can be set to off (fig. 16).
6
Airflow
m
/h
l/s
3
83/47/29/21
23,1/13/8/6
Static pressure
Power
Pa max
W max
27
2,5
Sound pressure
dB(A) @3m
26/23/13/11