Error messages
Codes
Meanings
E1
Longer inlet time.
Not reaching
E3
required
temperature
E4
Overflow
WARNINGS! If overflow occurs, turn off the main water supply before calling service.

PRODUCT FICHE

This dishwasher s product fiche has been setup in conformity with EU Regulation No 1059/2010.
Brand
Model
Rated capacity (standard place settings)
Energy efficiency class
From A
(most efficient) to D (least efficient)
+++
Annual energy consumption (AEc)
Energy consumption (Et) of the standard cleaning cycle
Power consumption in off mode (P
Power consumption in left-on mode (P
Annual water consumption (AWc)
Drying efficiency class on a scale from G (least efficiency)
to A (most efficiency)
Standard program
Program time for the standard cleaning cycle
Duration of the left-on mode (T
Sound power level
Built-in appliance Y/N
Product dimension (W x D x H mm)
Rated voltage / frequency
Rated power
Water pressure
Energy consumption
and the consumption of the low power modes. Actual energy consumption will depend on how the
appliance is used.
Water consumption 2
consumption will depend on how the appliance is used.
The standard program is the standard cleaning cycle to which the information in the label and the
fiche relates, that this program is suitable to clean normally soiled tableware, and that it is the most
efficient program in terms of combined energy and water consumption.
Possible Causes
Tap is not opened, or water inlet
is restricted, or water pressure is
too low.
Malfunction of heating element
Some dishwasher parts are
leaking.
)
0
)
1
)
1
188
kWh per year, based on 280 standard cleaning cycles using cold water fill
380
litres per year, based on 280 standard cleaning cycles. Actual water
Thomson
THPRIMO245
10
+++
A
kWh/annum
188
0.
658
kWh/cycle
0.45 W
0.49 W
2380 litres
A
ECO
50
19 minutes
8
15
minutes
44 dB(A) re 1 pW
Yes
448 x 550 x 815 mm
220-240V~ 50Hz
1760-2100 W
0.04 1 MPa
GB-27
Possible Solution
Turn on the water tap.
Check the water inlet hose
is not blocked. Increase
inlet water pressure.
Contact the
after-sales service to
replace the heating
element.
Contact the
after-sales service to repair
and replace parts.