Troubleshooting
If your THoMAS HYGIENE T2 does not work to your satisfaction first use the check list given below whether the cause of the irregularity is just a
small matter before you contact the Customer Service Department.
Occurring irregularities,
faulty functions
General (all functions)
v The appliance cannot be started up
Dust vacuuming (dry vacuuming)
v Dust is discharged when vacuuming
v Suction power slowly decreases
v Suction power is too low
Wash cleaning
v The suction power decreases suddenly
v Water is escaping from the blow-out
openings on the appliance
v Large amounts of water gather in the
suction area (a few drops are absolutely
normal)
v Excessive foam formation in the waste
water tank
v No cleaning agent is provided although
the pump is switched on
v There is too much residual moisture in the
system and liquid is no longer sucked up
properly
22
- Reasons, elimination
Are the mains connection cable, plug and plugbox in order? → Before checking disconnect the
main power supply plug; any necessary repairs are only to be carried out by an authorised
specialist
Is the appliance switched on? → Check
Has the hygiene box incl. HEPA bag been fitted in keeping with the instructions for use?
If the HEPA bag is full or has a defect → put in another one.
Are nozzles, suction tube or suction hose blocked by coarse dirt? → Flexing the tube during
operation will release any dust and dirt blocking the tube and clear the stoppage.
Are nozzles, suction tube or suction hose blocked by coarse dirt? → Flexing the tube during
operation will release any dust and dirt blocking the tube and remove the stoppage.
Is the housing cover properly locked? → Check.
Is the electronic suction power controller set to MIN? → Set suction power to MAX (orange
lamp lights up).
Is the mechanical suction power controller on the hand grip open? → Close the slider on the
hand grip.
Is the waste water tank full (float has responded)? → Empty the tank.
Is the appliance standing at an angle (has the float responded? → Stand the appliance up
straight and switch the appliance off and on again.
Is the float in the waste water tank dirty and is the float switch no longer functional, i.e. it
does not respond when the tank is full? Clean float and hinge.
Has the waste water tank been fitted together with the anti-swash insert, wet filter and motor
protection filter? → Switch off the appliance immediately, dry the appliance and fit missing parts.
Are seals and sealing surfaces extremely dirty? → Clean.
Did you forget to fit the wet filter for the anti-splash grid.
Did you use the original THoMAS cleaning agent? → Replace
Is there any cleaning agent in the spraying agent tank? → Refill
Is the spraying nozzle blocked? → Place nozzle in luke-warm water and afterwards draw out
strongly.
Is the tank connection opening blocked? → Remove fresh water tank and thoroughly suck out
the tank connection opening (connection point between fresh water tank and housing) with
the crevice nozzle to remove any possible contamination and dirt.
Is the electronic suction power controller set to MIN? → Set suction power to MAX (orange
lamp lights up).
Is the mechanical suction power controller on the hand grip open? → Close the slider on the
hand grip.
Is the nozzle really flat on the floor? → Hold nozzle at a slightly greater incline.