Note: The values shown in the display are actual temperature and humidity inside the appliance.
New set point effects will depend on internal load and environmental conditions. It is therefore necessary to
wait until new internal conditions are stable.
This appliance has been designed as a maturing cabinet.
It can also be used as a serving appliance. All you need to do is to adjust internal temperature according to your
needs. As a general rule, white wine should be served between 6 and 10ºC and red wine between 15 and 18ºC.
Please consider that being born as a maturing cabinet, the internal temperature raising and dropping rate is
slow. The time needed to achieve serving temperatures, depending on internal load and climate conditions, can
be large.
Before doing any cleaning, disconnect the appliance from
the electricity (by pulling out the plug or turning off the
general switch in your home).
Unload any bottles for internal cleaning or if you need to
move your appliance.
WARNING: Do not damage the refrigeration circuit.
Cleaning and Maintenance
The inside of the appliance should be cleaned on a
periodic basis. Use only a soft cloth, water and a mild
detergent solution to clean the appliance. Do not use
abrasive, acetone, spirit or alcohol based cleaning
products.
After cleaning the inside, rinse it well with clean water
and dry carefully.
Once the appliance is cleaned, turn it on, following the
instructions in Chapter "Starting up the appliance".
Charcoal filter replacement
In order to keep adequate air quality, the charcoal filter
(I) must be replaced once a year. Pull the old filter from
its support and push the new one, being careful while
aligning it.
You can purchase original filters at your retailer.
The controller will show a "FIL" message when it is time
to change the filter. In face of that message, just press any
key to stop the buzzer, change the filter and press release

MAINTAINING THE APPLIANCE

(pag.31 / IMG 2)
8
– Water around 150 ml
A
– Do not place in the drainpipe
B
In case, you are facing a low humidity inside the cabinet
(mainly in the initial phase of the installation), adjust it
with small amount of water as shown in the illustration.
filter key (17) to reset counter and message. Default time
is 365 days but you will be able to change it pressing filter
key for 3 seconds and then increasing or decreasing the
number of days with the UP and DOWN keys (13/14),
press again (17) to exit setting mode.
Imputing zero days will disable the filter function.
Condenser cleaning
Once a year it is advisable to clean the rear grid
(condenser). You can vacuum clean it or use a soft brush.
Doing so will maintain a low energy consumption level.
When not in use
Should the unit not be used for a long period of time,
disconnect the plug from the mains and leave the door
open to avoid the formation of mould and unpleasant
odours.
Check if the drain (H) is clean. If necessary, remove all
water with a sponge and clean the water discharge hole
with the supplied wiper