ALARMS AND WARNING MESSEGES
The controller will display an alarm or a warning code if something is not according to expectations. This message is
displayed alternating with internal temperature until alarm condition recovers.
The Buzzer can be Silenced by Pressing any Key. Please refer to the following table to understand the meaning and
what should be done to overcome alarm or warning situations.
Code
Cause
Open Door Warning
dA
FIL
Charcoal Filter Change
HA
High Temperature Alarm
LA
Low Temperature Alarm
HHA
High Humidity Alarm
Low Humidity Alarm
HLA
P1
Thermostat Probe Failure
P3
Humidity Probe Failure
Action
Close the door unless you need it opened for a loading
/unloading operation. In this case, you can stop the buzzer by
pressing any key. When finished, make sure to close the door,
the LED light should go off.
Until this fault is recovered, the appliance will stop all cooling
and heating actions.
Change the charcoal filter and reset the message pressing the
filter key (17). See chapter "Maintaining the appliance" for
details.Even if this message is present, the appliance will
continue his normal operation.
This message will appear if the controller is not able to bring
internal temperature to set point threshold.
Check if the appliance is installed correctly and if the climate
conditions of the room are according to specifications (refer to
chapter "Installation").
If there has been a change in temperature or humidity set point,
a major load change or a long open door status, press any key to
stop the buzzer and wait some hours for the appliance to
stabilise.
If you are not able to sort the problem, contact your retailer.
This message will appear if the controller is not able to bring
internal humidity to safe range.
Check if the appliance is installed correctly and if the climate
conditions of the room are according to specifications (refer to
chapter "Installation").
If there has been a change in temperature or humidity set point,
a major load change or a long open door status, press any key to
stop the buzzer and wait a few hours for the appliance to
stabilise.
If you are not able to sort the problem, contact your retailer.
Contact your retailer, with this fault your appliance will stop
working.
Contact your retailer, with this fault your appliance will stop
humidity control.