MAINTENANCE

Setting the De-Liming Detection Mode

When de-liming detection mode is enabled, the controller will
indicate the presence of excessive lime build-up in humidified
models by showing "DE-L" on the CABINET TEMPERATURE
display. Use the following procedure to set de-liming detection
mode "on" or "off."

TROUBLESHOOTING GUIDE

WARNING
This unit must be serviced by trained and qualified
personnel only. Service by unqualified personnel may lead
to electric shock or burn.
Symptom
LED lights not working.
Unit operates, but is not
circulating air inside cabinet.
Unit is plugged in, but nothing
works
Unit is operational, but rotating
rack (if equipped) does not
turn.
Unit is not producing any "hot
air" inside cabinet.
Unit is heating, but is producing
too much humidity inside the
cabinet causing steam inside
unit.
Unit is heating, but is not
producing
humidity
inside
cabinet. "LO H20" not flashing on
display and unit is full of water.
Unit is heating, but is not
producing
humidity
inside
cabinet. "LO H20" flashes on
display and unit is full of water.
Probable Cause
Loose wire connection.
LED driver defective.
LED light strip defective.
Blower motor is defective.
The correct voltage may not be supplied to blower.
No power to unit.
Power cord connections are loose or disconnected.
Power cord is damaged.
Defective POWER ON/OFF (I/O) switch.
Proximity switch was not relocated after door
reversal.
Proximity magnet or proximity switch not
working properly.
Incorrect voltage is supplied to rack motor.
Safety high-limit is tripped or open.
Incorrect voltage supplied to heating element.
Blower motor is not working.
Air heating element is defective.
Humidity control is set too high.
Air temperature is set too low.
Humidity control is defective.
Incorrect voltage supplied to water heating
element or heating element is defective.
When using distilled water, no minerals are being
sensed by low water probe.
Low water protection system is malfunctioning. Contact an Authorized Hatco Service Agent or Hatco for assistance.
1. Press and hold either the
• When de-liming detection mode is enabled, the
CABINET TEMPERATURE display shows "L-ON" for
three seconds.
• When de-liming detection mode is disabled, the
CABINET TEMPERATURE display shows "L-OF" for
three seconds.
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.

Corrective Action

Verify wire connection is secure.
Contact Authorized Service Agent or Hatco for assistance.
Replace the LED light strip. Refer to the "Replacing an LED
Light Strip" in the MAINTENANCE section.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Check electrical receptacle and verify that power supply
matches specifications on unit. If receptacle is not working,
check circuit breaker and reset, or plug unit into a different
known working receptacle.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
See "Relocating the Proximity Switch" in the INSTALLATION
section of this manual.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Adjust the humidity control to a lower setting.
Adjust the temperature to a higher setting.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
On initial fill, add one teaspoon of salt to the water reservoir.
14
English
key or
key for four seconds.
WARNING
Form No. FSDM-0119