Dispensing Agent Connection To The Liquid Dispensing Mixing Compartment - Miele PWM 514 Mode D'emploi

Masquer les pouces Voir aussi pour PWM 514:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

en - Installation
184
Dispensing agent connection to the liquid dispensing
mixing compartment
Connections 1 and 2 are provided for viscous agents. These con-
nectors are sealed and need to be drilled open using an 8 mm drill
bit.
Connections 1 and 2 can also be used for high pressure dispensing
systems with water injection.
The dispensing systems must be fitted with a separate drinking wa-
ter safety feature in accordance with EN 61770 and EN 1717.
Care must be taken to drill through the first wall (1) only, as there is a
deflecting wall (2) 10 mm behind it.
If the drilled out connections are no longer required, they must be re-
sealed.
Connections 3 to 12 are provided for liquid dispensing. These con-
nectors are sealed and must be cut to suit the diameter of the hose
with a suitable hacksaw. If opened connectors are no longer required,
they must be resealed.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pwm 520

Table des Matières