Abus PR2700 Notice De Montage Et D'utilisation page 23

Masquer les pouces Voir aussi pour PR2700:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PV1820: Frame through-bolting of the lock casings in case of unstable mounting options (e.g. thin
lightweight construction walls)
Mounting (use longer M8 screws if necessary):
1. Drill through holes Ø 9 mm in the corresponding position through the door frame. Drill out
from the outside Ø 13 mm and 35 mm deep.
2. Insert the threaded sleeve including the metal plates into the screw holes from the outside
as shown in the illustration (Fig. 29) and screw it together through the lock casing from the
inside (use washers if necessary). Shorten the screws if necessary.
3. Press the cover on from the outside.
Fig. 29
PA1018N: Mounting set for outward opening doors
Note: Screw connection suitable for door thicknesses of 38 to 80 mm.
Drill through holes ø 9 mm, in the corresponding position through the door panel and drill out
ø 13 mm and 35 mm deep from the outside.
Insert the screw sleeves including the metal plates into the screw holes from the outside as
shown in the illustration (Fig. 30) and screw together through the security door bar from the
inside. Shorten the screws if necessary.
Press the cover on from the outside.
Fig. 30
44
PSB2700: Door guard unit for opening the door a crack
Fig. 31
I. Assembly
2.
Note:
Until the lock casing is assembled on the lock side, the as-
sembly instructions for the PR2700 apply. Please check in
advance whether there is enough space for the complete
1.
lock casing. The bar overhang from the lock casing of the
lock for two-turn closing is approx. 47 mm.
Installing the lock casing on the lock side.
1. When using PSB2700, first remove the plastic plug
1.
2.
3.
ø 4 mm
Fig. 32
1.
2.
Fig. 33
2.
II. Operation
1.
Fig. 34
Fig. 35
Replace lock tube insert:
from the lock tube (if necessary, use a screwdriver to
lever it through the small hole / Fig. 31).
Insert the bolt end cap for door guard function and
tighten all the way with self-tapping screw 5 x 12
from the PSB2700 set.
Drill out the cross-head of the screw with an HSS
drill bit Ø 4 mm (Fig. 32) and apply e.g. a touch-up
stick or lubricant to the outline of the hole (to
protect from corrosion).
Installing the lock casing:
2. The lock casing is pre-mounted for DIN right opening
doors. For DIN left opening doors, the door guard
will need to be shifted accordingly (Fig. 33).
3. Lock the bolt by turning the key once and remove
the key (door guard position). Loosen bolt clamping
screw 1. (Fig. 34) and slide the lock tube until a
suitable mounting point for the lock casing has
been reached. Make sure there is a stable surface for
screwing. Even out the folding thickness with
mounting plate and plastic washers, if necessary.
For folding thicknesses < 16 mm, we recommend
using the lock body support. Mark the lock casing
position. Tighten the door bar adjusting screw 1.
(Fig. 34).
4. For mounting the lock casing see „Mounting the lock
casing with mounting plate". Then knock the safety
plugs into the hexagon socket of the screws. (Fig. 35).
1. Close the bolt on the reinforced door bar lock until it
is in locked position.
The door can now be opened in locked position. In
locked position, the door guard will latch under its
own weight. The door guard must be raised in order
to unlock it
2. The door guard unit is maintenance free. Do not use
aggressive or caustic cleaning agents to clean the
surface.
GB
45

Publicité

Table des Matières
loading

Table des Matières