Design 2
EZN3A0055H045
ƒ
EZN3A0055H045U
ƒ
How to wire the filter:
1. Deenergise the control cabinet and fuse it against re−energisation.
2. Connect the connection cables "load" 2 to the basic device.
–
Observe the mounting instructions for the basic device!
3. Attach the PE conductor to the PE stud 1 with the ring cable lug.
–
Observe tightening torque!
4. Connect the mains cables to the screw terminal "line" 0.
–
Observe tightening torque!
EDKZN3B045 DE/EN/FR 3.0
Electrical installation
l
Mounting steps
EZN−075b
4
47