PROBLEM
VIBRATION
MOTOR OVERLOADING
TOO MUCH AIR
FAN DOES NOT OPERATE
EXCESSIVE NOISE
M0112_NOV 2020
Canarm Ltd. - Corporate Head Office
Tel: (613) 342-5424
FAN TROUBLE SHOOTING GUIDE
POSSIBLE CAUSES
Impeller or sheaves loose
Belts not tensioned properly
Bent shaft
Out of balance impeller
Loose fasteners
Loose or worn bearings
Drive misalignment
Fan not properly installed
Mismatched belts
Out of balance sheaves
Improper fan installation
Static pressure higher than design
Impeller rotating in the wrong direction
Improper fan speed
Defective motor
Fan speed higher than design
Filters missing
Static pressure lower than design
Fan speed higher than design
Lack of electricity to the fan
Fan wired improperly
Broken or missing belt
Missing or blown fuses
Overload protection has broken circuit
Defective motor
Impeller or sheaves loose
Belts not properly tensioned
Sheaves not properly aligned
Impeller out of balance
Sheaves out of balance
Bent shaft
Bearings defective or need lubrication
Worn belts
Vibration or lack of isolation
Loose fasteners
High velocity air