Télécharger Imprimer la page

Canarm BPT18-34A-1 Mode D'emploi Et Liste Des Pièces

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

BATHROOM
EXHAUST FANS
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use unapproved
fans over a bathtub or shower that does not include a GFCI protected circuit.
2.
Installation work must be carried out by a qualified person(s) in accordance with all local and safety codes including the rules for
fire-rated construction.
3.
To reduce the risk of fire, always vent fans to the exterior and in compliance with local codes. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
4.
Install ductwork in a straight line with minimal bends.
5.
Use 120 V, 60 Hz for the electrical supply and properly ground the unit. Follow all local safety and electrical codes.
6.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
7.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
8.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
9.
CAUTION-For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
BEFORE YOU BEGIN
1. Carefully unpack and remove the unit from the carton.
2. Check to make sure you have all components listed in the tables shown below.
3. If any components are missing, please contact the manufacturer.
ITEM
Quick Connect
Long Wood Screw
(4 x 30mm)
Screw #1
(4 x 12mm)
(For use with Suspension
Brackets 2 & 3)
Screw #2
(4 x 8mm)
(For use with Suspension
Bracket 1)
BPT18-34A-1
(For bathroom size up to 105 ft
2
)
PRODUCT SPECIFICATIONS
MODEL
DUCT DIAMETER
BPT18-34A-1
4"
BPT18-54A-1
6"
BPT18-34A-1-M & BPT18-54A-1-M-04_15_20
BPT18-34A-1
BPT18-54A-1
PICTURE
QUANTITY
*May not be
exactly as shown
BPT18-54A-1
(For bathroom size up to 200 ft
VOLTAGE
Hz
POWER CONSUMPTION
120
60
31 WATTS
120
60
42 WATTS
ITEM
3
Fan Unit
8
2
Grill
1
Suspension
Bracket 1
Suspension
Bracket 2
Suspension
Bracket 3
2
)
AIR DELIVERY @ 1" WG (CFM)
110
150
PICTURE
*May not be
exactly as shown
NOISE
1 SONE
1.5 SONE
QUANTITY
1
1
1
1
1
WEIGHT
13.1 LBS
15.7 LBS
Page 1 of 4

Publicité

loading

Sommaire des Matières pour Canarm BPT18-34A-1

  • Page 1 (For bathroom size up to 200 ft PRODUCT SPECIFICATIONS MODEL DUCT DIAMETER VOLTAGE POWER CONSUMPTION AIR DELIVERY @ 1” WG (CFM) NOISE WEIGHT BPT18-34A-1 4” 31 WATTS 1 SONE 13.1 LBS BPT18-54A-1 6” 42 WATTS 1.5 SONE 15.7 LBS BPT18-34A-1-M & BPT18-54A-1-M-04_15_20 Page 1 of 4...
  • Page 2: Dimensions

    BPT18-34A-1 & BPT18-54A-1 BATHROOM EXHAUST FANS DIMENSIONS 15.86” 12.5” 13.27” BPT18-34A-1 BPT18-54A-1 12.6” 13.27” 15.5” 15.86” 1.2” 7.95” 8.75” 8.31” 9.1” 7.9” 6” OUTLET 4” OUTLET 10.4” 10.3” 10.28” 10.36” FIGURE 1 INSTALLATION INSTRUCTIONS WARNING: TURN OFF ELECTRICITY AT BREAKER BOX...
  • Page 3 BPT18-34A-1 & BPT18-54A-1 BATHROOM EXHAUST FANS INSTALLATION INSTRUCTIONS CONTINUED... FIGURE 5 CIRCULAR DUCT CONNECTION (FIGURE 5) DUCT a) Install a circular duct to the outlet and secure it With duct tape or clamps to the outlet. b) Install the duct with a gradient of 1˚ ~ 2˚ to the outside.
  • Page 4 WARRANTY CANARM Ltd. warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid, and found to be defective.
  • Page 5 SPÉCIFICATIONS DU PRODUIT MODÈLE DIAM. DU CONDUIT VOLTAGE CONSOMMATION ÉNERGIE DÉBIT D’AIR @ 1” WG (PCM) BRUIT POIDS BPT18-34A-1 4” 31 WATTS 1 SONE 13.1 LBS BPT18-54A-1 6” 42 WATTS 1.5 SONE 15.7 LBS BPT18-34A-1-M-FR & BPT18-54A-1-M-FR-04_15_20 Page 1 de 4...
  • Page 6 BPT18-34A-1 & BPT18-54A-1 VENTILATEUR DE SALLE DE BAIN DIMENSIONS 15.86” 12.5” 13.27” BPT18-34A-1 BPT18-54A-1 12.6” 13.27” 15.5” 15.86” 1.2” 7.95” 8.75” 8.31” 9.1” 7.9” SORTIE SORTIE 6” OUTLET 4” OUTLET DE 6” DE 4” 10.4” 10.28” 10.3” 10.36” ILLUSTRATION 1 MODE D’INSTALLATION...
  • Page 7 BPT18-34A-1 & BPT18-54A-1 VENTILATEUR DE SALLE DE BAIN MODE D’INSTALLATION SUITE... ILLUSTRATION 5 CONDUIT CIRCULAR CIRCULAIR CONNEXION DU CONDUIT (ILLUST. 5) DUCT a) Poser un conduit circulaire à la sortie et fixer le avec un ruban adhésif à conduit ou une pince.
  • Page 8: Entretien

    CANARM LTD. garantie que ce nouveau ventilateur sera exempt de toutes défectuosités dans la fabrication et les matériaux pour une période d’un an à compter de la date d’achat par l’utilisateur original. CANARM LTD. Réparera ou remplacera à son choix, une pièce ou l’unité...

Ce manuel est également adapté pour:

Bpt18-54a-1