Télécharger Imprimer la page
Canarm IDL Serie Mode D'emploi Et Liste Des Pièces

Canarm IDL Serie Mode D'emploi Et Liste Des Pièces

Souffleurs de conduit en ligne

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IDL SERIES
INLINE DUCT BLOWERS
OPERATION INSTRUCTIONS AND PARTS MANUAL
IDL SERIES MODELS: IDL07, IDL09, IDL10, IDL12, IDL15
GENERAL SAFETY
Rotating parts, (pulleys, shafts and belts) on fans should not be exposed. Where these components are not protected by ductwork, cabinets
or covers, appropriate guards should be employed to restrict exposure to rotating parts. Access doors should not be opened with the fan
operating to avoid foreign objects being drawn into the system. On initial start-up, a careful inspection should be carried out to ensure no
foreign material is present which could become airborne in the system.
Read installation and operation instructions carefully before attempting to install, operate or service Canarm/Delhi IDL Series Blowers.
Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
DIMENSIONS (INCHES)
A
B
C
D
E
IDL07
29
23
13
8 1/2
15
IDL09
32
26
16
10 7/16
18
IDL10
36
32
19
24
12
IDL12
42
36 21 5/8 13 7/8
28
IDL15
46
42
25
16 3/4
32
BEFORE YOU BEGIN
Inspect unit for damage, report any shipping damage to carrier. Check all fasteners, re-tighten as required. Rotate the blower wheel by
hand to ensure free rotation. If rubbing occurs, loosen the set screw(s), re-position the wheel to the shaft center, re-tighten set screws.
INSTALLATION
Install the mounting brackets to the
holes on the blower sides to achieve an
ideal mounting position.
Use the 5/16 hole plug in 7010053 parts
bag to block the holes not needed.
Suspend the unit by threaded rod
(provided by others) through the holes
on the mounting brackets.
NOTE: Flexible inlet & outlet duct
collars and vibration isolator are
recommended to minimize
vibration transmission and lower
the noise level.
IDL-M-07_20_16
C D
F
G
H
I
Max HP Shaft Dia.
1/8
7/8 22 1/2 25 5/8
3/4
1/8
7/8 25 1/2 28 5/8
3/4
5/8
7/8 29 1/2 34 5/8
1 1/2
1/2
1
33 7/8 38 5/8
1 1/2
1/2
35 7/8 49 5/8
3
1
RIGID MOUNT
B
A
F
E
G
Weight
(without motor)
3/4
43 lbs
3/4
55 lbs
3/4
65 lbs
3/4
82 lbs
1
140 lbs
G
I
H
Threaded rod provided by others.
Vibration isolator sold as accessory.
WHEEL ROTATION
E
D
Mounting brackets
shipped loose.
Can be installed at
3 different levels
FIGURE 1
ISOLATOR MOUNT
Page 1 of 5

Publicité

loading

Sommaire des Matières pour Canarm IDL Serie

  • Page 1 Read installation and operation instructions carefully before attempting to install, operate or service Canarm/Delhi IDL Series Blowers. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
  • Page 2 IDL SERIES INLINE DUCT BLOWERS INSTALLATION Continued... ACCESSING MOTOR & DRIVES Caution: Clear/remove the objects below the blower before installation/maintenance. Keep clear of the area directly below the blower. When swinging down the hinge base to access the motor & drives, always support the bottom of the unit and gradually release the base to the stable position.
  • Page 3 IDL SERIES INLINE DUCT BLOWERS MOTOR, PULLEYS & BELT 1. Mount the blower pulley on the blower shaft and tighten the set screw securely on the key of the shaft. 2. Mount the motor pulley on the motor shaft. Leave some clearance between the pulley and the motor end bell. Tighten the set screws on the key of the motor shaft.
  • Page 4 IDL SERIES INLINE DUCT BLOWERS OPERATION 1. Complete the electrical connections, energize the unit momentarily and ensure proper wheel rotation. (see Fig, 1). 2. Apply full power. 3. With all ducts attached, the access doors in place and the air system in full operation, measure the motor current and ensure that it is less than the rated full load motor amperage as indicated on the motor nameplate.
  • Page 5 WARRANTY Canarm Ltd. Air Moving Products are guaranteed for a period of one year against manufacturing defects in material and workmanship when operating under normal conditions. Liability is limited to the replacement of defective parts. Labour and transportation costs are not included.
  • Page 6 Lire le mode d’installation et d’emploi attentivement avant de poser ou d’opérer ou d’entretenir le Souffleur Série IDL de Canarm/Delhi. Le défaut de se conformer aux instructions peut entraîner des blessures et/ou dommages à la propriété. Conservez ces instructions pour référence ultérieure.
  • Page 7 SÉRIE IDL SOUFFLEURS DE CONDUIT EN LIGNE INSTALLATION suite... ACCÉDER AU MOTEUR ET AUX ENTRAÎNEMENTS Mise en Garde : Enlever tous les objets sous le souffleur avant l’installation/entretien. Rester loin de la partie directement située sous le souffleur. Lorsque vous basculez la charnière pour accéder au moteur ou aux entraînements, soutenir le dessous de l’appareil et le relâcher graduellement pour le stabiliser en position.
  • Page 8 SÉRIE IDL SOUFFLEURS DE CONDUIT EN LIGNE MOTEUR, POULIES & COURROIES 1. Poser la poulie du souffleur sur l’arbre du souffleur et serrer la vis d’arrêt fermement contre la clé de l’arbre. 2. Poser la poulie sur l’arbre du moteur. Laisser un espace entre la poulie et la cloche de finition du moteur. Serrer la vis d’arrêt fermement contre la clé...
  • Page 9 SÉRIE IDL SOUFFLEURS DE CONDUIT EN LIGNE OPÉRATION 1. Compléter les connexions électriques, et remettre la tension temporairement le temps de vérifier la rotation adéquate de la roue (voir Illustration 1). 2. Mettre sous tension. 3. Avec tous les conduits fixés, les portières d’accès en place le système d’air en pleine opération, mesurer le courant émis par le moteur et assurez-vous qu’il est moindre que l’ampérage indiqué...
  • Page 10 GARANTIE Les produits de déplacement d’air de Canarm Ltée sont garantis pour une période d’un an contre tous défauts dans la fabrication et la main-d’œuvre lorsque le produit est opéré dans des conditions normales. Notre responsabilité se limite au remplacement des pièces défectueuses.

Ce manuel est également adapté pour:

Idl07Idl09Idl10Idl12Idl15