Remedy Of Faults - Oase ProfiClear Premium Notice D'emploi

Masquer les pouces Voir aussi pour ProfiClear Premium:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69
8

Remedy of faults

Malfunction
No flow of water
Water flow insufficient
Water remains cloudy
Unusual noises in the drum
Fish missing
Rinsing channel blocked
Filter drum is partially
soiled, cannot be cleaned
In a pump fed system,
water is flowing via the
emergency overflow
Time-dependent cleaning
function (interval) does not
start
No display on the control
system
Oil film in the Drum Filter
Module
Possible cause
Filter pump not switched on
Supply to filter system or return to pond
blocked
Bottom drain, pipe or hose blocked
Hose kinked
Excessive loss in lines
Insufficient pump capacity
Water is extremely soiled
Dirt particles do not reach the drum filter
module
Too many pond animals
Screen elements clogged or damaged
Drum seal incorrectly positioned
Drum seal is damaged
Large dirt particles have collected in the filter
drum
Fish may have swum through a pipe into the
filter drum.
Large particles of dirt such as string algae
are blocking the dirt channel
Rinsing nozzles clogged
Screen elements clogged
Pump capacity too high
The control system checks the function of the
level detection device.
This check is started automatically if too
few automatic cleaning procedures have
been carried out.
Cable not connected
Control system has switched off due to
overheating (temperature switch)
Safety fuse has tripped due to a blockage of
the rinsing pump (excessive current
consumption)
Harmless food-grade oil may leak from a new
rinsing pump for a short time when first used
Remedy
Switch on the filter pump, connect the power plug
Clean the supply and/or return
Clean, replace if necessary
Check hose, and replace if necessary
Reduce line length to necessary minimum
Adjust the pump capacity accordingly
For AquaMax Eco Premium 12000, 16000,
switch off the SFC (Seasonal Flow Control)
function. SFC reduces the quantity of water by up
to 50 %.
Remove algae and leaves from the pond
If the water is particularly contaminated, change
30 % of the water to avoid damage to the fish
Optimise the water flow so that the skimmer
and/or the filter pump can draw in the dirt
particles.
Align the skimmer and/or filter pump in relation to
the water flow so that they can draw in dirt
particles.
Reduce number of pond animals
Clean or replace screen elements
Check the seating of the drum seal
Replace the drum seal
Remove a screen element and remove dirt
particles from the filter drum
Remove screen element, take the fish out of the
filter drum and return to the pond
Remove a screen element and clean the dirt
channel
Clean the rinsing nozzles, replace if necessary
Clean/decalcify the screen elements
Reduce the pump capacity
Wait. The check takes a maximum of 24 hours.
The check is completed once the level detection
function is triggered. An automatic cleaning
procedure is carried out.
If the level detection device is not triggered within
24 hours,
2 is displayed. The time-dependent
E
E
r
r
2
2
2
cleaning process is activated. (
messages)
Check cable connection
Protect the control system from heat and allow it to
cool down
The control system will switch back on
automatically when it has cooled down
Error message
6 alerts the user before the
E
r
6
E
r
6
6
control system overheats
Clean the rinsing pump (
Clean/remove the
rinsing pump)
Replace the fuse(
N)
Only use 5 × 20 mm, 8 A slow-blow / 250 V
safety fuse.
No measure is necessary
- GB -
System
63

Publicité

Table des Matières
loading

Table des Matières