INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are
present. In addition to the exhaust fan you should have:
1 - Grill
4 - Mounting Rails
1 - Damper Assembly (attached)
1 - Instruction/Safety Sheet
2. Remove the fan's venturi assembly, which is secured in place
with one screw through the venturi (Figure 1). This is a captive
screw and will stay installed in the venturi. Keep the venturi
assembly and the grill in the carton until needed so they do
not get damaged or lost.
Figure 1
3. Choose the location for your fan. To ensure the best air and
sound performance, it is recommended that the length of
ducting and the number of elbows be kept to a minimum, and
that insulated hard ducting be used. Larger duct sizes will
reduce noise and airflow restrictions. This fan will require at
least 6" of clearance in the ceiling or wall, and will mount
through drywall up to 3/4" thick. The
fan mounts to the joist using the
mounting tabs on the side of the
housing or between 16" or 24" on
center joists using the 4 provided
mounting rails.
4. Select the most convenient
electrical knockout and remove
using a straight-blade screw driver
(Figure 2).
SECTION 2
New Construction
1. Install the mounting rails on the housing and position the
housing next to the joist. Line up housing so that it will be
flush with the finished ceiling. Secure the ends of the rails
with screws or nails (not included) to the joists and slide the
housing into the final position (Figure 3).
210572088 Rev. C 7-05
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline
SECTION 4
Ducting
CAUTION:
AND NATIONAL BUILDING CODES.
1. Connect the ducting to the fan's duct collar (Figure 5). Secure
Figure 2
NOTE: If damper detaches from unit, reattach by snapping the
collar back onto the unit. It is designed to only fit one way.
www.airkinglimited.com
Housing
Joist
Figure 3
onto the ceiling material (Figure 4). Set housing aside and
cut opening, being careful not to cut or damage any electrical
or other hidden utilities. Install the rails on the housing and
position the housing in the previously cut hole so that it is
flush with the finished ceiling. Secure the ends of the rails
to the joists (Figure 3).
Joist
Figure 4
ALL DUCTING MUST COMPLY WITH LOCAL
in place using tape or screw clamp. Always duct the fan to
the outside through a wall or roof cap.
Ducting
Duct
Collar
Figure 5
Mounting Rails