PROBLEMS WITH YOUR WINE CELLAR?
You can solve many common Wine Cellar problems easily, saving you the cost of a possible service call.
Try the suggestions below to see if you can solve the problem before calling the servicer.
PROBLEM
Wine Cellar does not operate.
Wine Cellar is not cold enough.
Turns on and off frequently.
The light does not work.
Vibrations.
The Wine Cellar seems to make too much noise.
The door will not close properly.
Display "E1" or "E2".
Display "E3" or "E4".
Display "E7" or "E8".
All manuals and user guides at all-guides.com

TROUBLESHOOTING GUIDE

Not plugged in.
The appliance is turned off.
The circuit breaker tripped or there is a blown
fuse.
Check the temperature control setting.
External environment may require a higher
setting.
The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
The room temperature is hotter than normal.
A large amount of contents has been added to
the wine cellar.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly.
The door gasket does not seal properly.
Not plugged in.
The circuit breaker tripped or there is a blown
fuse.
The light button is "OFF".
Check to assure that the Wine Chiller is level.
The rattling noise may come from the flow of the
refrigerant, which is normal.
As each cycle ends, you may hear gurgling
sounds caused by the flow of refrigerant in your
Wine Cellar.
Contraction and expansion of the inside walls
may cause popping and crackling noises.
The Wine Cellar is not level.
The Wine Cellar is not level.
The door was reversed and not properly installed.
The gasket is dirty.
The shelves are out of position.
The temperature sensor in lower temperature
zone is failed. This sensor is connected to the
main control PCB in white color wires.
The defrost sensor is failed. This sensor is
connected to the main control PCB in red color
wires.
The temperature sensor in higher temperature
zone is failed. This sensor is connected to the
main control PCB in yellow color wires.